- Put the SIM cover back.
- Connect the GSM antenna to the FAKRA-D connector.
- Connect the GPS antenna to the FAKRA-C connector.
- For the connection to the DTE, connect the V24 link via the 9-pin Sub D cable.
- Connect the power cable to the continuous and regulated power source (for an automobile
application, see paragraph 5.2).
- Connect the power cable to the modem and turn ON the external power supply.
The modem is now ready.
Depending on the application installed in the equipment:
- Without application: corresponds to BootLoader.
- Standard library.
- The application ERCOGENER EaseLoc_Vx.
- The owner application.
we get different views. See paragraph below.
5.1.3
Checking the communication with the modem
5.1.3.1
Without application
The GenLoc 54e does not contain any application; it will return the menu of the BootLoader.
Connect the RS232 link between the DTE (COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
▪ Bits per second: 115 200 bps,
▪ Data bits: 8,
▪ Parity: None,
▪ Stop bits: 1,
▪ Flow control: without.
Use a communication software like Windows HyperTerminal ®.
Menu by default when there is no
application inside the equipment (example of display)
Bootloader V4.09 GL54 UA Gener Ublox (HWF1 rev D/E)
GSM voltage = 4325 mV
1 - Update application
2 - Erase objects
M - GSM direct access (external supply required)
A - Advanced
P - Power off
E - Exit
In the case where no communication can be established with the modem:
▪ Check the RS232 connection between the DTE and the modem (DCE),
▪ Check the configuration of the COM port of the DTE.