5.1.3.2
Standard library
The GenLoc 54e contains the standard library.
Connect the RS232 link between the DTE (COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
▪ Bits per second: 115 200 bps,
▪ Data Bits: 8,
▪ Parity: None,
▪ Stop Bits: 1,
▪ Flow control: without.
Use a communication software like Windows HyperTerminal ®.
Example of display when the standard library is present inside the equipment
*************************************************************
00:00:00 flash_start_flash: new Flash handle - WAIT
00:00:00 EGM_INIT_SOFTWARE_RESET
00:00:00 Ext2: EGM_FCM_EVENT_FLOW_OPENNED
00:00:00 READY
00:00:00 Gprs_Call_State : GPRS_CALL_INIT
00:00:00 UTC Time field not valid
00:00:00 Date field not valid
00:00:01 Supply status: External supply connected
00:00:02 Analog input 3 State H
00:00:02 sim inserted
00:00:02 PIN code not required
00:00:02 GSM Ready
00:00:03 +CCLK: "12/07/30,09:29:45+00"
00:00:03 Got GSM clock info
00:00:03 *** IMEI: 358696048201787, product: "GenLoc54e"
EaseLoc V300b2_EGM403b24 - GenLoc54e - LEON-G100-06S-00 - Thu Jun 21 09:18:01
2012
00:00:03 PHB Ready
00:00:03 sim ready
00:00:07 SMS Ready
00:00:09 Network ready
00:00:09 network_gprs_state: 1
00:00:23 CREG OK : 1
Send the command AT+EGM3
The modem returns the version of the library
+EGM3: genapi V4.04, Date: Thu Nov 15 13:57:42 2012
In the case where no communication can be established with the modem:
▪ Check the RS232 connection between the DTE and the modem (DCE),
▪ Check the configuration of the COM port of the DTE
For more information about these AT commands and their associated parameters, see the documents