EG_GenLoc54e_1040_UG_002_UK
Page 44 / 86
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
(1*) with
+CMEE=1
. The command
AT+CMEE=1
allows the display of extended error codes; it is possible to
save it with the command
AT&W
.
By default, some event codes
+EGEVT
allow the display of status change of the SIM card (card
present, card ready
…) and allow to know some status of the modem (modem ready after a RESET…),
see the Command List of ERCOGENER.
(2*) with
+CRC=1
. The command
AT+CRC=1
allows in the case of an incoming call to display an extended
message that indicates the channel called. This message corresponds to the type of number called:
voice, data, it is possible to save it with the command
AT&W
.
Examples:
If the VOICE number is called, the modem replies: +CRING : VOICE
If the DATA number is called, the modem replies: +CRING : REL ASYNC
5.11 Turning OFF the modem
The modem contains the EGM standard library (see the documents
"EG_EGM_CL_xxx_yy" of
ERCOGENER); in this case, it is strongly advised to un-register from the network with the command
AT+COPS=2
There is no particular action to do on the GPS part before turning it OFF.
When the battery is present, a mechanism allows to stop completely the application if the
external power supply is unplugged, and also to prepare the modem for storage or transport, in
order to limit high discharges of the battery.
If the device is not used, it has to be deactivated by sending the following command:
If the modem has an application developed with EGM
,
Cut the external power supply of the modem
send the command
AT+GPIOSET=35,0
If the modem does not contain any embedded application
, via the Boot-Loader menu
Bootloader V4.09 GL54 UA Gener Ublox (HWF1 rev D/E)
GSM voltage = 4330 mV
1 - Update application
2 - Erase objects
M - GSM direct access (external supply required)
A - Advanced
P - Power off
E - Exit
Cut the external power supply of the modem.
Else
Enter "P"
Important Note
: The switching of the battery and its auto-maintain will be automatically