EPSON Stylus C87/C88/D88
Revision A
TROUBLESHOOTING
Troubleshooting With LED Error Indications
33
3.2.1 Fatal Error
Check the parts according to the contents of the fatal error, and replace the parts as necessary.
C H E C K
P O I N T
As the most recent fatal error (fatal error code) is stored in the
EEPROM (Address: 0AH), it is possible to check the error by using
the adjustment program.
Classification
Item
Description
Remedy
DC Error
PID aveTi max Error
Something is wrong with the CR motor.
Check the parts listed below, and replace them as necessary.
• CR Motor
• CR Encoder
• CR Encoder Scale
• Timing Belt
• Main Board
• Connectors and harnesses of each motor or encoder
PID Overspeed Error
Carriage movement speed is abnormal.
PID Lock Error
Carriage has been locked for a certain period of time due to
external factors.
PID Reverse Rotation Detection Error
The number of the carriage reverse rotation has exceeded the
predetermined times due to external factors.
Encoder Abnormality Error (CR Driving
Time Over Error)
One-pass movement cannot be completed though the CR
motor has been driving longer than the specified time.
Load Positioning Overspeed Error
Abnormal carriage movement speed is detected during load
positioning control.
Load Positioning Lock Error
It is detected that the carriage has been locked for a certain
period of time during load positioning control.
Load Positioning Cumulative Movement
Distance Error
The cumulative movement distance during the load
positioning control has exceeded the given level
Head Error
Transistor Environment Temperature
Abnormality Error
The environment temperature of the transistor that generates
head driving waveform on the Main board is abnormal.
Check the parts listed below, and replace them as necessary.
• Printhead
• Head FFC
• Main Board
Pre-printing X-HOT Detection Error
During pre-printing X-Hot detection, the temperature of the
head driver IC has exceeded the given level for more than two
seconds.
Post-flushing X-HOT Detection Error
During post-printing X-Hot detection, the temperature of the
head driver IC has exceeded the given level for more than two
seconds.
Содержание Stylus C87
Страница 1: ...EPSONStylusC87 C88 D88 Color Inkjet Printer SEIJ05 002 SERVICE MANUAL ...
Страница 5: ...Revision Status Revision Date of Issue Description A August 1 2005 First Release ...
Страница 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 23: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 29: ...I C H A P T E R 3 TROUBLESHOOTING ...
Страница 36: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Страница 80: ...C H A P T E R 5 ADJUSTMENT ...
Страница 92: ...C H A P T E R 6 MAINTENANCE ...
Страница 98: ...C H A P T E R 7 APPENDIX ...
Страница 100: ...104 PX V630 EPSON Stylus C88 D88 D88 Photo Edition C87 No 1 Rev 01 C617 ACCE 001 400 ...
Страница 101: ...108 105 111 102 Rev 01 C617 CASE 001 112 107 101 109 103 110 PX V630 EPSON Stylus C88 D88 D88 Photo Edition C87 No 2 ...
Страница 102: ...PX V630 EPSON Stylus C88 D88 D88 Photo Edition C87 No 3 B A Rev 01 C617 ELEC 001 300 200 ...
Страница 107: ...Model PX V630 Stylus C87 C88 D88 Board C528 MAIN Rev M Sheet 1 1 ...
Страница 108: ...Model PX V630 Stylus C87 C88 D88 Board C528 PSH Rev A Sheet 1 1 ...
Страница 109: ...Model PX V630 Stylus C87 C88 D88 Board C528 PNL Rev A Sheet 1 1 ...