ADJUSTMENT
TF Adjustments
266
Confidential
[Blue]:
Button or menu name on the program screen /
[Black]:
Button or menu name on the operation panel of the printer
3.
Set the gauge unit to the base. (No specific direction is specified for the gauge
unit)
4.
Adjust the gauge panel to the front so that you can check the value easily.
5.
Remove the gauge unit by holding its base.
6.
Tighten the screw of the gauge.
Figure 4-72. Setting the gauge unit
7.
Set the gauge unit on the origin position adjuster.
Figure 4-73. Setting the gauge unit on the origin position adjuster
8.
Press the ON/OFF button to turn on the gauge.
9.
Press and hold the SET button to reset the value to “0”.
Figure 4-74. Gauge
Gauge unit
Base of gauge unit
Screw
Adjust screen to the front.
Origin position adjuster
Gauge unit
SET button
ON/OFF button