SC-F2000
Revision C
ADJUSTMENT
Head Related Checks and Adjustments
247
Confidential
[Blue]:
Button or menu name on the program screen /
[Black]:
Button or menu name on the operation panel of the printer
PROCEDURE
1.
Remove the CR Cover.
2.
Loosen the screws that secure the PG adjustment levers on both sides.
3.
Adjust the PG by moving the PG adjustment levers up or down.
4.
After the adjustment is completed, try the PG check again. Repeat the check and
adjustment until the PG falls within the standard values.
Figure 4-48. PG Adjustment Levers
C H E C K
P O I N T
Move the levers on both sides by the same amount when adjusting
the PG.
PG adjustment levers
Move the lever up: CR comes up.
Move the lever down: CR comes down.