![Epson S1C17 Series Скачать руководство пользователя страница 158](http://html.mh-extra.com/html/epson/s1c17-series/s1c17-series_manual_107781158.webp)
S1C17 CORE MANUAL
Seiko Epson Corporation
7-99
(Rev. 1.2)
ld.cf %rd, %rs
Function
Transfer data to the coprocessor and get the flag status
Standard) co_dout0
←
rd
, co_dout1
←
rs
, psr(C, V, Z, N)
←
co_cvzn
Extension 1) Unusable
Extension 2) Unusable
Code
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 1 1 0 1
r d
0 0 0 1
r s
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flag
IL IE C V Z N
– –
↔
↔
↔
↔
|
|
|
| |
Mode
Src: Register direct
%rs
=
%r0
to
%r7
Dst: Register direct
%rd
=
%r0
to
%r7
CLK
One cycle
Description
(1) Standard
ld.cf %rd,%rs
; co_dout0 data = rd, co_dout1 data = rs
Transfers data set in the
rd
and
rs
registers to the coprocessor and gets the flag status of the
coprocessor to the C, V, Z, and N flags in the PSR.
(2) Delayed slot instruction
This instruction may be executed as a delayed slot instruction by writing it directly after a
branch instruction with the “d” bit.