ld.b [imm7], %rs
Function
Signed byte data transfer
Standard) B[
imm7
]
←
rs
(7:0)
Extension 1) B[
imm20
]
←
rs
(7:0)
Extension 2) B[
imm24
]
←
rs
(7:0)
Code
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
1 1 0 1 0 0
r s
imm7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flag
IL IE C V Z N
– – – – – –
|
|
|
| |
Mode
Src: Register direct
%rs
=
%r0
to
%r7
Dst: Immediate data (unsigned)
CLK
One cycle
Description
(1) Standard
ld.b [imm7],%rs
; memory address = sp + imm7
The eight low-order bits of the
rs
register are transferred to the memory address specified with
the 7-bit immediate
imm7
.
(2) Extension 1
ext imm13
; = imm20(19:7)
ld.b [imm7],%rs
; memory address = imm20, imm7 = imm20(6:0)
The
ext
instruction extends the displacement to a 20-bit quantity. As a result, the eight low-
order bits of the
rs
register are transferred to the memory address specified with the 20-bit
immediate
imm20
.
(3) Extension 2
ext imm4
;
imm4(3:0) = imm24(23:20)
ext imm13
; = imm24(19:7)
ld.b [imm7],%rs
; memory address = imm24, imm7 = imm24(6:0)
The two
ext
instructions extend the displacement to a 24-bit quantity. As a result, the eight
low-order bits of the
rs
register are transferred to the memory address specified with the 24-bit
immediate
imm24
.
(4) Delayed slot instruction
This instruction may be executed as a delayed slot instruction by writing it directly after
a branch instruction with the “d” bit. In this case, extension of the immediate by the
ext
instruction cannot be performed.
Example
ext 0x1
ld.b [0x1],%r0
; B[0x81]
←
8 low-order bits of r0