Maintenance 11. Lithium Battery and Boards
LS20 Rev.4
141
11.2 Replacing the Resolver Board
After battery board and parts have been replaced (motors, reduction gear units, timing
belts, ball screw spline unit, etc.), the manipulator cannot operate properly because a
mismatch exists between the origin stored in each motor and its corresponding origin
stored in the controller.
After replacing the parts, it is necessary to match these origins.
The process of aligning the two origins is called “Calibration”.
Refer to
Maintenance: 13. Calibration
to execute the calibration.
Resolver Board
Removal
(1) Turn OFF the controller.
(2) Remove the resolver plate from the connector
plate.
Truss screw: 4-M4
×
10
4-M4
×
10
(3) Disconnect three batteries connectors and the
cable connector.
Connector: M/C signal, X10, X20.
Battery
Connecter
X10
M/C
Signal
X20
(4) Remove the resolver board from the resolver
plate.
Hexagon socket head cap bolts: 4-M3
×
4
4-M3
×
4
Содержание LS20
Страница 1: ...Rev 4 EM179R3533F SCARA ROBOT LS20 series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS20 series Rev 4 ...
Страница 8: ...vi LS20 Rev 4 ...
Страница 12: ...TABLE OF CONTENTS x LS20 Rev 4 ...
Страница 14: ......
Страница 29: ...Setup Operation 2 Specifications LS20 Rev 4 17 LS20 804S Standard Model ...
Страница 31: ...Setup Operation 2 Specifications LS20 Rev 4 19 LS20 804C Cleanroom Model ...
Страница 33: ...Setup Operation 2 Specifications LS20 Rev 4 21 LS20 A04S Standard Model ...
Страница 35: ...Setup Operation 2 Specifications LS20 Rev 4 23 LS20 A04C Cleanroom Model ...
Страница 71: ...Maintenance This volume contains maintenance procedures with safety precautions for LS20 series Manipulators ...
Страница 72: ......
Страница 92: ...Maintenance 4 Cable 80 LS20 Rev 4 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Страница 176: ...Maintenance 14 Maintenance Parts List 164 LS20 Rev 4 ...