EPSON
LQ-570e/LQ-580
Revision
C
Disassembly
and Assembly
Disassembly
and Assembly
80
Figure
4-10. C293 MAIN Board Removal
When
connecting wires, check following condition;
n
Blue
marking side on CN12 and CN13 must locate at “1” of
connector.
n
All
wires should not touch each other.
n
All
wires must be fully connected in correct position.
Make
sure
to
match
the
connector
color
each
other.
n
Locking
peg on connector must be fully locked.
n
Should
not damage or bend pins.
n
Do
not catch cable from the power supply board assembly
between
the main board assembly and the shield plate.
CBP-Tight
(3x12)
I/F
Grounding Plate
I/F
Board Guide; B
CBP-Tight
(3x12)
C A U T I O N
n
Must
use the wrist band while handling the main board
assembly.
n
Be
careful with the sharp edges of the shield plate to avoid injury.
A D J U S T M E N T
R E Q U I R E D
After
replacing the C293 MAIN Board, perform the default setting
and
Bi-d adjustment to store the new data into the EEPROM on the
MAIN
board.
Содержание LQ-570e
Страница 8: ...C H A P T E R 1 PRODUCT DESCRIPTION ...
Страница 46: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 57: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 70: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 93: ...C H A P T E R 5 ADJUSTMENT ...
Страница 101: ...C H A P T E R 6 MAINTENANCE ...
Страница 106: ...C H A P T E R 7 APPENDIX ...
Страница 119: ...EPSON LQ 570e LQ 580 Revision C Appendix Components Layout 119 Figure 7 3 C293PSB Component Layout ...
Страница 120: ...EPSON LQ 570e LQ 580 Revision C Appendix Components Layout 120 Figure 7 4 C293PSE Component Layout ...
Страница 127: ......
Страница 128: ......
Страница 129: ......