EPSON
LQ-570e/LQ-580
Revision
C
Disassembly
and Assembly
Disassembly
and Assembly
91
4.2.9.10
Ribbon Drive (RD) Assembly Removal
1.
Remove
the printer mechanism. (See 4.2.7 "Printer Mechanism Removal".)
2.
Remove
the upper head cable and the lower head cable from the printhead. (See 4.2.1
"Pre-disassembly
Procedures".)
3.
Remove
the platen cover and remove platen. (See 4.2.8 "Platen Removal".)
4.
Remove
the hexagon nut, release lever, washer and the bushing parallel adjust.
Remove
the adjust parallel bushing. (See 4.2.9.8 "Carriage Assembly Removal".)
5.
Remove
the harness of PG detector. (See 4.2.9.4 "PG (Platen Gap) Detector Removal")
6.
Remove
the harness of HP detector from the left frame. (See 4.2.3 "HP (Home
Position)
Detector Removal")
7.
Remove
4 CBS (3x8, F/ZN) screws securing the left frame to the printer mechanism,
and
remove the left frame.
8.
Remove
CBS-Tight C(P2) (3x8, F/ZN) securing the ribbon drive assembly from the
top
and remove CBB (3x8) screw securing it from the bottom.
9.
Release
the ribbon dive assembly engaging with the drive roller assembly and remove
the
ribbon dive assembly.
Figure
4-28. RD Assembly Removal
C B S - T i g h t C ( P 2 ) ( 3 x 8 , F / Z N )
R i b b o n D r i v e A s s e m b l y
C B B ( 3 x 8 )
F R A M E , F R O N T
R O L L E R A S S E M B L Y , D R I V E
Содержание LQ-570e
Страница 8: ...C H A P T E R 1 PRODUCT DESCRIPTION ...
Страница 46: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 57: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 70: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 93: ...C H A P T E R 5 ADJUSTMENT ...
Страница 101: ...C H A P T E R 6 MAINTENANCE ...
Страница 106: ...C H A P T E R 7 APPENDIX ...
Страница 119: ...EPSON LQ 570e LQ 580 Revision C Appendix Components Layout 119 Figure 7 3 C293PSB Component Layout ...
Страница 120: ...EPSON LQ 570e LQ 580 Revision C Appendix Components Layout 120 Figure 7 4 C293PSE Component Layout ...
Страница 127: ......
Страница 128: ......
Страница 129: ......