Insert the loop-back connector. Then select
to start the
check.
First, the program checks the serial port control lines to see that
they are able to change from high to low and vice versa. No
messages are displayed during this part of the test unless an error
occurs.
The second test is an echo back check during which the port
sends data to itself in a fixed data format, at all the possible
baud rates. When this test begins, you see these messages:
RS232C echo back check - at various baud rates
Current baud rate is 15
Current test data is 00
Each baud rate is tested in turn, and the display informs you of
the progress of the test. If the port does not become ready
correctly, a timeout error occurs. If any data received does not
match the data sent, a verify error occurs, and the computer
reports the transmitted and received data at the time of the
error.
The final test is an echo back check during which the port
sends data to itself at 9600 baud, using various data formats. At
the start of the test, you see these messages:
RS232C echo back check-with various data formats
Current data format: 5 data bits, 1 stop bit,
parity - NONE
Current test data is 00
Once again, if any data received does not match the data sent, a
verify error occurs, and the computer reports the transmitted
and received data at the time of the error.
C-30
Performing
System Diagnostics
Содержание Equity IIe
Страница 1: ......
Страница 4: ...EPSON E Q U I T Y I I e User s Guide Y18699100101 ...
Страница 140: ...For more information on using EEMM286 SYS see your MS DOS Reference Manual 4 50 Using MS DOS with Your Equity Ile ...
Страница 225: ... C 40 Performing System Diagnostics ...
Страница 239: ...D 14 Physically Formatting a Hard Disk ...
Страница 241: ...E 2 Hard Disk Drive Types ...
Страница 243: ...E 4 Hard Disk Drive Types ...
Страница 276: ......