2. Installation
2.6 EtherNet/IP Network Construction
Network Configuration
A EtherNet/IP network is configured as shown in the following figure.
Network inside
the factory, etc
Waterproof
Ethernet switch
Waterproof
slave
Waterproof
slave
Node
Node
Node
Node
Ethernet switch
Node
Node
Node
Ethernet switch
Node
Node
Node
There are two types of the node: master and slave. The master controls a network and gathers
data from its slaves. The slaves, including external I/O and other devices, output data in
response to the master’s output order and informs the master of its input status.
You can install masters anywhere in the network. One master node can control up to 127
nodes.
Universal Ethernet cable is used for EtherNet/IP. Use a proper cable such as environmental
resistance and refraction resistance that fulfills the environment.
For details, see the website of ODVA. (http://www.odva.org/)
Wiring
Wirings are conformed to EtherNet/IP
connection protocol.
You can use the generic Ethernet hub or Ethernet switch for the EtherNet/IP. However, be
sure to a use product complying with the industrial standards or noise resistant Ethernet
cable (STP cable). If you use an office use product or UTP cable, it may causes
communication errors and may not offer the proper performance.
)
NOTE
Fieldbus I/O Rev.6
25
Содержание EM07ZS1647F
Страница 1: ...Rev 6 EM07ZS1647F EPSON RC Option Fieldbus I O ...
Страница 2: ...E PSON RC Option Fieldbus I O Rev 6 ...
Страница 8: ...vi Fieldbus I O Rev 6 ...
Страница 11: ...Table of Contents 5 Maintenance Parts List 151 Appendix A applicomIO Upgrade 153 Fieldbus I O Rev 6 ix ...
Страница 12: ...Table of Contents x Fieldbus I O Rev 6 ...
Страница 80: ...2 Installation 68 Fieldbus I O Rev 6 ...
Страница 88: ...3 Operation 76 Fieldbus I O Rev 6 ...
Страница 164: ...5 Maintenance Parts List 152 Fieldbus I O Rev 6 ...
Страница 168: ...Appendix A applicomIO Upgrade 156 Fieldbus I O Rev 6 ...