EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
168
FIP-29
Panel Message
Jam E
Jam D, E
Possible parts that caused the error
Troubleshooting
ROLL ASSY PRE-REGI
ROLL-PINCH
ROLL-REGI METAL
ROLL REGI RUBBER
ACTUATOR-REGI
SENSOR REGI
MOTOR-PH
HARNESS-ASSY P/H1
HARNESS-ASSY P/H2
PWBA MCU
LV/HVPS
HARNESS ASSY MAIN
Step
Check
Yes
No
1
Paper size check
Is the paper size compliant with the
specifications?
Go to Step[2].
Use paper of
size compliant
with the
specifications.
2
Paper size setting check
Does the size of the paper in use match the
size of the paper set on the control panel?
Go to Step[4].
Change the
paper size
setting, and
proceed to step
[3].
3
Does the error recur when a test print is
made by dialog operations?
Go to Step[4].
End of
procedure
4
Shape and operation check of ROLL ASSY
PRE-REGI and ROLL-PINCH
Open CHUTE ASSY-REAR.
Are ROLL ASSY PRE-REGI and ROLL-
PINCH attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step[5].
Replace or re-
attach ROLL in
question.
5
Shape and operation check of ROLL-REGI
METAL and ROLL REGI RUBBER
Open CHUTE ASSY-REAR.
Are the ROLL-REGI and ROLL REGI
RUBBER attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step[6].
Replace or re-
attach ROLL in
question.
6
Operation check of ACTUATOR-REGI
Does ACTUATOR-REGI move smoothly
without any damage? Does ACTUATOR-
REGI enter the sensor sensing area when there
is paper? Does it leave the sensor sensing area
when there is no paper?
Go to Step[7].
Replace
ACTUATOR-
REGI.
(p.335)
7
Operation check of SENSOR REGI
The voltage of P408-12
↔
P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensing area of SENSOR
REGI, and is 5 VDC when it leaves the
sensing area?
Go to Step[8].
Go to Step[11].
8
24 VDC power supply check to MOTOR-PH
The voltage of P409-6
↔
P409-5 on PWBA
MCU is 24 VDC?
Go to Step[9].
Go to Step[14].
9
Continuity check of HARNESS-ASSY P/H1
Disconnect P/J405 and P/J604 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
J409-1
↔
P604-6
J409-2
↔
P604-5
J409-3
↔
P604-4
J409-4
↔
P604-3
J409-5
↔
P604-2
J409-6
↔
P604-1
Go to Step[10].
Replace
HARNESS-
ASSY P/H1.
Step
Check
Yes
No
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...