EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
166
11
Operation check of SENSOR REGI
The voltage of P408-12
↔
P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensor sensing area, and is 5
VDC when it leaves the sensing area?
Go to Step [17].
Go to Step [12].
12
5 VDC power supply check to SENSOR REGI
The voltage of P408-10
↔
P408-11 on
PWBA MCU is 5 VDC?
Go to Step [13].
Go to Step [15].
13
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-10
↔
J603-3
J408-11
↔
J603-2
J408-12
↔
J603-1
Go to Step [14].
Replace
HARNESS-
ASSY P/H1.
14
Continuity check of HARNESS-ASSY P/H2
Disconnect P/J603 and P/J102 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
P603-10
↔
J102-3
P603-11
↔
J102-2
P603-12
↔
J102-1
Replace
SENSOR
REGI.
(p.336)
Replace
HARNESS-
ASSY P/H2.
15
5 VDC power supply check to PWBA MCU
The voltage of P410-3
↔
P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU.
(p.404)
Go to Step [16].
16
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3
↔
J502-3
J410-4
↔
J502-4
Replace LV/
HVPS.
(p.407)
Repair broken
or shorted part.
Step
Check
Yes
No
17
24 VDC power supply check to P/H MOTOR
The voltage of P409-6
↔
P409-5 on PWBA
MCU is 24 VDC?
Go to Step [18].
Go to Step [20].
18
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J409 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J409-1
↔
P604-6
J409-2
↔
P604-5
J409-3
↔
P604-4
J409-4
↔
P604-3
J409-5
↔
P604-2
J409-6
↔
P604-1
Go to Step [19].
Replace
HARNESS-
ASSY P/H1.
19
Check after replacement of MOTOR-PH
Replace MOTOR-PH.
(p.337)
Does the error recur when a test print is made?
Replace PWBA
MCU.
(p.404)
End of
procedure
20
24 VDC power supply check to PWBA MCU
The voltage of P410-5/6
↔
P410-7/8 on
PWBA MCU is 24 VDC?
Replace PWBA
MCU.
(p.404)
Go to Step [21].
21
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5
↔
J502-5
J410-6
↔
J502-6
J410-7
↔
J502-7
J410-8
↔
J502-8
Replace LV/
HVPS.
(p.407)
Repair broken
or shorted part.
22
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-1
↔
J603-12
J408-2
↔
J603-11
Go to Step [23].
Replace
HARNESS-
ASSY P/H1.
Step
Check
Yes
No
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...