EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
221
FIP-63
Panel Message
Replace Photocondctr
Possible parts that caused the error
Troubleshooting
Photoconductor Unit
SENSOR TNER FULL
HARNESS ASSY MAIN
PWBA MCU
LV/HVPS
Step
Check
Yes
No
1
Attachment check of Photoconductor Unit
Is Photoconductor Unit attached correctly?
Go to Step [4].
Re-attach, and
go to step [2].
2
Does the error recur when the power is
turned ON?
Go to Step [3].
End of
procedure
3
Check after replacement of
Photoconductor Unit
Replace Photoconductor Unit.
Does the error occur when the power is turned
ON?
Go to Step [4].
End of
procedure
4
Operation check of SENSOR TNER FULL
(Toner Full Sensor)
Remove Photoconductor Unit.
The voltage of P413-11
↔
P413-10 on
PWBA MCU is 0 VDC when the sensor
sensing area is blocked, and is 5 VDC when
the sensing area is not blocked?
Replace PWBA
MCU.
(p.404)
Go to Step [5].
5
5 VDC power supply check to SENSOR
TNER FULL
The voltage of P413-12
↔
P413-10 on
PWBA MCU is 5 VDC?
Go to Step [6].
Go to Step [8].
6
Continuity check of HARNESS ASSY MAIN
Do all of the wiring below have normal
continuity?
J413-10
↔
J617-3
J413-11
↔
J617-2
J413-12
↔
J617-1
Go to Step [7].
Repair broken
or shorted part.
7
Continuity check of HARNESS ASSY TNR
FULL
Disconnect P/J617.
Do all of the wiring below have normal
continuity?
P617-1
↔
J126-3
P617-2
↔
J126-2
P617-3
↔
J126-1
Replace
SENSOR
TNER FULL.
(p.374)
Repair broken
or shorted part.
8
5 VDC power supply check to PWBA MCU
The voltage of P410-3
↔
P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU.
(p.404)
Go to Step [9].
9
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3
↔
J502-3
J410-4
↔
J502-4
Replace LV/
HVPS.
(p.407)
Repair broken
or shorted part.
Step
Check
Yes
No
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...