EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
172
22
Continuity check of HARNESS ASSY
2BTR SENS
Disconnect P/J620 from HARNESS ASSY
2BTR SENS.
Do all of the wiring below have normal
continuity?
P620-1
↔
J111-3
P620-2
↔
J111-2
P620-3
↔
J111-1
Replace
SENSOR
FUSER IN.
(p.344)
Replace
HARNESS
ASSY 2BTR
SENS.
23
Shape and operation check of CAM ASSY-
2ND
Does CAM ASSY-2ND move smoothly
without any damage, and does it enter the
sensor sensing area?
Go to Step [24].
Replace CAM
ASSY-2ND.
(p.350)
24
Operation check of SENSOR 2BTR
RETRACT
Remove 2ND BTR ASSY.
(p.348)
The voltage of P418-6
↔
P418-5 on PWBA
MCU is 0 VDC when CAM ASSY-2ND
enters the sensing area of SENSOR 2BTR
RETRACT, and is 5 VDC when it leaves the
sensing area?
Go to Step [27].
Go to Step [25].
25
5 VDC power supply check to SENSOR
2BTR RETRACT
Disconnect P/J418 from PWBA MCU.
The voltage of P418-4
↔
P418-5 on PWBA
MCU is 5 VDC?
Go to Step [26].
Go to Step [39].
26
Continuity check of HARNESS ASSY ADC
Disconnect P/J418 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J418-4
↔
J112-3
J418-5
↔
J112-2
J418-6
↔
J112-1
Replace
SENSOR 2BTR
RETRACT.
(p.356)
Replace
HARNESS
ASSY ADC.
Step
Check
Yes
No
27
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J403 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J403-1
↔
J600-3
J403-2
↔
J600-2
J403-3
↔
J600-1
Go to Step [28].
Repair broken
or shorted part.
28
24 VDC power supply check to MOT ASSY
MICRO (2ND BTR Retract Motor)
The voltage of P403-3
↔
P403-2 on PWBA
MCU is 24 VDC?
Go to Step [29].
Go to Step [36].
29
Check after replacement of MOT ASSY
MICRO
Replace MOT ASSY MICRO.
(p.399)
Does the error recur when a test print is made?
Replace PWBA
MCU.
(p.407)
End of
procedure
30
Operation check of EXIT SENSOR in
FUSER ASSY
The voltage of P417-8
↔
P417-7 on PWBA
MCU is 0 VDC when ACTUATOR enters the
sensing area of EXIT SENSOR, and is
5 VDC when it leaves the sensing area?
Go to Step [33].
Go to Step [31].
31
5 VDC power supply check to EXIT
SENSOR in FUSER ASSY
Allow FUSER ASSY to cool down
before performing work.
Remove FUSER ASSY.
(p.388)
The voltage of connector J614A-7
↔
J614A-6
that connects FUSER ASSY on the printer is 5
VDC?
Go to Step [32].
Go to Step [38].
Step
Check
Yes
No
W A R N I N G
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...