EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
200
FIP-47
Panel Message
Service Req E525
Possible parts that caused the error
Troubleshooting
Photoconductor Unit
SENSOR ASSY ADC
Toner Cartridge K
Toner Cartridge Y
Toner Cartridge M
Toner Cartridge C
HARNESS ASSY ADC
SENSOR HUM & TEMP
HARNESS ASSY MAIN
ROS ASSY
PWBA MCU
LV/HVPS
Step
Check
Yes
No
1
Check of connection between Photoconductor
Unit and CONDUCTOR attached to frame
Remove Photoconductor Unit.
Is the contact surface of Photoconductor Unit
and CONDUCTOR attached to the frame
deformed or are there foreign objects on the
surface?
Clean, and go to
Step [2].
Go to Step [2].
2
Check of dirt and foreign bodies on surface
of SENSOR ASSY ADC
Are there any dirt or foreign bodies on the
SENSOR ASSY ADC surface?
Clean, and go to
Step [3].
Go to Step [4].
3
Does the error recur when the power is
turned ON?
Go to Step [4].
End of
procedure
4
Check after replacement of Toner Cartridge
Replace Toner Cartridge of each color.
Does the error recur when the power is turned
ON?
Go to Step [5].
End of
procedure
5
Check after replacement of
Photoconductor Unit
Replace Photoconductor Unit.
Does the error recur when the power is turned
ON?
Go to Step [6].
End of
procedure
6
5 VDC and 24 VDC power supply check to
SENSOR ASSY ADC
The voltage of P422-2
↔
P422-4 on PWBA
MCU is 24 VDC?
And the voltage of P422-8
↔
P422-4 is 5
VDC?
Go to Step [7].
Go to Step [14].
7
Continuity check of HARNESS ASSY ADC
Disconnect P/J422 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J422-8
↔
J431-1
J422-4
↔
J431-5
J422-2
↔
J431-7
Go to Step [8].
Replace
HARNESS
ASSY ADC.
8
Check after replacement of SENSOR ASSY
ADC
Replace SENSOR ASSY ADC.
(p.353)
Does the error recur when the power is turned
ON?
Go to Step [9].
End of
procedure
9
Check of 5 VDC power supply to SENSOR
ASSY HUM & TEMP
The voltage of P413-4
↔
P413-2 on PWBA
MCU is 5 VDC?
Go to Step [10].
Go to Step [14].
10
Continuity check of HARNESS ASSY MAIN
Disconnect P/J413 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J413-1
↔
J104-4
J413-2
↔
J104-3
J413-3
↔
J104-2
J413-4
↔
J104-1
Go to Step [11].
Repair broken
or shorted part.
Step
Check
Yes
No
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...