EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
162
FIP-27
Panel Message
Jam MP, E
Jam D, E
Possible parts that caused the error
Troubleshooting
ROLL MSI
HOLDER ASSY RETARD MSI
CHUTE ASSY PAPER GUIDE
ROLL ASSY-PRE REGI
ROLL-PINCH
ACTUATOR-REGI.
SENSOR REGI
HARNESS-ASSY P/H1
HARNESS-ASSY P/H2
PWBA MCU
LV/HVPS
MOTOR-PH
HARNESS ASSY MAIN
CLUTCH ASSY PRE REGI
Step
Check
Yes
No
1
Check of the paper
Is the paper loaded in the paper tray wrinkled
or torn?
Replace with
new, dry paper.
Go to Step [2].
2
Paper size setting check
Does the size of the paper in use match the
size of the paper set on the control panel?
Go to Step [4].
Change the
paper size
setting, and
proceed to step
[3].
3
Does the error recur when a test print is
made?
Go to Step [4].
End of
procedure
4
Shape and operation check of ROLL ASSY
of MSI section
Remove MSI.
(p.304)
Are ROLL MSI, HOLDER ASSY RETARD
MSI, CHUTE ASSY PAPER GUIDE, and
other parts attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step [5].
Replace ROLL
ASSY in
question.
5
Shape and operation check of ROLL
ASSY-PRE REGI and ROLL-PINCH
Open CHUTE ASSY-REAR.
Are ROLL ASSY-PRE REGI and ROLL-
PINCH attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step [6].
Replace ROLL
in question.
6
Does the error recur when a test print is
made?
Go to Step [7].
End of
procedure
7
Check of the paper position
Is the leading edge of the paper passing
through PRE REGI ROLL?
Go to Step [8].
Go to Step [20].
8
Operation check of ACTUATOR-REGI
Does ACTUATOR-REGI move smoothly
without any damage? Does it enter the sensor
sensing area when there is paper? Does it
leave the sensor sensing area when there is no
paper?
Go to Step [9].
Replace
ACTUATOR-
REGI.
(p.335)
9
Operation check of SENSOR REGI
The voltage of P408-12
↔
P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensor sensing area, and is 5
VDC when it leaves the sensing area?
Go to Step [15].
Go to Step [10].
10
5 VDC power supply check to SENSOR REGI
The voltage of P408-10
↔
P408-11 on
PWBA MCU is 5 VDC?
Go to Step [11].
Go to Step [13].
Step
Check
Yes
No
Содержание C1100 - AcuLaser Color Laser Printer
Страница 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Страница 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Страница 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 485: ...C H A P T E R 5 ADJUSTMENT ...
Страница 491: ...C H A P T E R 6 MAINTENANCE ...
Страница 510: ...C H A P T E R 7 APPENDIX ...
Страница 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Страница 561: ...EPSON AcuLaser C1100 Revision B APPENDIX Circuit Diagrams 561 7 7 Circuit Diagrams C567MAIN Total 4 pages ...
Страница 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Страница 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Страница 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Страница 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...