Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
188
Confidential
4.3.1.3 Upper Housing (Artisan 700/PX700W/TX700W)
Parts/Components need to be removed in advance:
Scanner Unit/Upper Left Housing/Paper Guide Top Assy
Removal procedure
1.
Remove the screw (x1) and release the Grounding Wire.
Figure 4-210. Releasing the Grounding Wire
2.
Release the hooks (x5) of the Panel Unit Front Cover. (See
Fig. 4-211
)
3.
While pushing the Panel Lock Button, slide the Panel Upper Cover in the
direction of the arrow to release the hook (x8) of the Panel Upper Cover, and
remove the Panel Upper Cover.
Figure 4-211. Removing the Upper Housing (1)
C H E C K
P O I N T
The disassembly/reassembly procedures for Artisan 800/PX800FW/
TX800FW differ from those of Artisan 700/PX700W/TX700W, see
4.2.2.5 "Upper Housing"
(p107)
for the procedures.
C A U T I O N
The Grounding Wire is attached to the frame with a screw. Be
careful not to deform the frame when removing the screw.
C.B.S. 3x6 (8±1Kgfcm)
Grounding
Wire
Panel Unit Front Cover
Panel Lock Button
Panel Unit
Panel Upper Cover
Hook of the Panel Upper Cover
Hook of the Panel Unit Front Cover