Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly Procedures
173
Confidential
4.2.5.5 Cover Open Sensor
Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit/Scanner Upper Housing
Removal procedure
1.
Release the hooks (x2) of the Sensor Cover, and remove the Sensor Cover
from the Scanner Lower Housing.
Figure 4-174. Removing the Cover Open Sensor (1)
2.
Disconnect the Cover Open Sensor FFC from the connector of the Cover
Open Sensor, and remove the Cover Open Sensor from the Scanner Lower
Housing.
Figure 4-175. Removing the Cover Open Sensor (2)
C H E C K
P O I N T
Sensor Cover
Artisan 800/PX800FW/
TX800FW
Hook
Sensor Cover
Artisan 700/PX700W/
TX700W
When attaching the Cover Open Sensor, insert it into the space
inside the ribs (x2)
of the Scanner Lower Housing as shown
in
Fig. 4-174
.
Figure 4-176. Attaching the Cover Open Sensor
Cover Open Sensor
Cover Open Sensor FFC
Cover Open Sensor
Rib
Содержание Artisan 700 Series
Страница 7: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 42: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 48: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 189: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 225: ...Confidential C H A P T E R 6 MAINTENANCE ...