Disassembly Procedures
150
Confidential
4.2.4.14 PF Motor
Parts/Components need to be removed in advance:
Main Frame
Removal procedure
1.
Push the Tensioner in the direction of the arrow and remove the PF Timing
Belt.
Figure 4-117. Removing the PF Timing Belt
2.
Remove the screw (x1) that secures the Spacer, and remove the Spacer. (See
Fig. 4-118
.)
3.
Remove the Compression Spring.
Figure 4-118. Removing the PF Motor (1)
4.
Remove the Tensioner together with the Driven Pulley.
Figure 4-119. Removing the PF Motor (2)
C H E C K
P O I N T
The Main Frame becomes unstable once it is removed from the
Base Frame. Be careful not to deform the frame during
performing the following procedures.
Refer to
4.2.4.11 Main Frame (p144)
for the Parts/Components
need to be removed before removing the Main Frame.
C A U T I O N
Be careful not to touch the PF Scale with bare hands.
Be careful not to damage or contaminate the PF Scale.
Be careful not to lose the Driven Pulley Shaft.
PF Timing Belt
Tensioner
Left side
C.C.S. 3x6 (9±1Kgfcm)
Spacer
Compression Spring
Positioning hole & dowel
Driven Pulley
Tensioner
Dowel
Protrusion
Tension Holder
reinforcing plate
Содержание Artisan 700 Series
Страница 7: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 42: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 48: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 189: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 225: ...Confidential C H A P T E R 6 MAINTENANCE ...