Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly Procedures
119
Confidential
FAX Board (IF-B Board) (Artisan 800/PX800FW/TX800FW only)
1.
Disconnect the I/F-B FFC from the FAX Board. (See
Fig. 4-43
.)
2.
Remove the screws (x4) that secure the Shield Plate FAX, and remove the
Shield Plate FAX from the Upper Shield Plate M/B.
Figure 4-43. Removing the FAX Board (1)
3.
Remove the screws (x4) that secure the FAX Board and remove the FAX
Board from the Upper Shield Plate M/B.
Figure 4-44. Removing the FAX Board (2)
Upper Shield Plate M/B
Top
Shield Plate FAX
Rear
C.B.S. 3x6 (4±1Kgfcm)
C.P. 3x6 (4±1Kgfcm)
I/F-B FFC
Dowel & groove
Align the positioning holes (x2) of the Main Board with the
dowels (x2) of the Upper Shield Plate M/B. (See
Fig. 4-42
.)
When installing the Main Board, tighten the screws in the order
shown in
Fig. 4-42
.
Align the dowels (x2) of the Lower Shield Plate M/B with the
grooves (x2) of the Upper Shield Plate M/B. (See
Fig. 4-41
.)
Align the positioning holes (x2) of the FAX Board with the
dowels of the Upper Shield Plate M/B. (See
Fig. 4-44
.)
When installing the FAX Board, tighten the screws in the order
shown in
Fig. 4-44
.
Align the grooves (x2) of the Shield Plate FAX with the dowels
(x2) of the Upper Shield Plate M/B. (See
Fig. 4-43
.)
Align the positioning hole (x1) of the Main Board with the dowel
(x1) of the Upper Shield Plate M/B. (See
Fig. 4-40
.)
C.B.S. 3x6 (4±0.5Kgfcm)
1
2
3
4
Upper Shield Plate M/B
FAX Board
Positioning hole & dowel
Содержание Artisan 700 Series
Страница 7: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 42: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 48: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 189: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 225: ...Confidential C H A P T E R 6 MAINTENANCE ...