EPSON AcuLaser C8500
Revision C
Chapter 4
Diagnostics
4-46
4.2.5.12 EEPROM Read
This lets you read and check the data stored in the MCU PWB
EEPROM(NVM).
NOTE: Code_EP (NVM number) must be entered in 2 bytes in order
from the least significant.
NOTE: Status data is displayed in 4 bytes in order from the least
significant.
NOTE: There are three kinds of data of 1Byte, 2Byte and 4Byte in
Code_EP (NVM number). But, be careful with the status
because it becomes the indication of 4Byte completely.
1Byte of the lowest rank in 4Byte becomes Data of the
appropriateness NVM number by the thing of 1Byte, and other
3Bytes data indicates data of other NVM numbers.
2Byte of the lowest rank in 4Byte becomes Data of the
appropriateness NVM number by the thing of 2Byte, and other
2Bytes data indicates data of other NVM numbers.
NOTE: When data is a negative value, values decrease from [FFh]: [-1]
= [FFh], [-2] = [FFh], etc.
NOTE:When MCU PWB is exchanged, though it is being made a
principle that exchange of EEPROM (NVM : U2) is done, begin
to read the following NVM number from MCU PWB before the
exchange surely, and do [EEPROMRead], and write down value
when exchange of EEPROM isn't made. (Do Log Save.) And,
recommend it when you do Read Out of the following NVM
number and write down value to grasp use conditions if
necessary when others maintain it.
Table 4-15. EEPROM Read Parameter
DIAGON command: [75]
DIAGOFF command: [76]
DIAG Command (EEPROM Read) : [90 05 XX XX]
DIAG Command (EEPROM Read) : Unnecessary
Parameter
Function
Data (hex)
1
Diagnostics Type
05 : EEPROM Read
2
Code_EP
NVM number (see “2.6.15 NVM List”)
3
Code_EP
NVM number (see “2.6.15 NVM List”)
4
Data
[Status only] data
5
Data
[Status only] data
6
Data
[Status only] data
7
Data
[Status only] data
Status present ( [90 05 XX XX XX XX XX XX])
EX) [Command]
90 01 0E 07
EX) [Status]
90 05 EC 02 A0 86 01 00
DIAGSTART Command
NVM Number 748(2ECh):
EEPROM Read
DIAGSTART Command
EEPROM Read
NVM Number 748(2ECh):
The accumulation value
for the BELT CLEANER ASSY
The accumulation value
for the BELT CLEANER ASSY
Data: 100000(186A0h)
Содержание AcuLaser C8500
Страница 12: ......
Страница 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Страница 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Страница 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Страница 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Страница 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Страница 139: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 62 No toner reset flow Figure 2 63 No Toner Reset Flow ...
Страница 150: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 73 Figure 2 71 C287MAIN Board Circuit Diagram Cooling fan ...
Страница 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Страница 269: ...C H A P T E R 4 DIAGNOSTICS ...
Страница 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Страница 480: ...C H A P T E R 6 MAINTENANCE ...
Страница 503: ...C H A P T E R 7 APPENDIX ...
Страница 522: ...EPSON AcuLaser C8500 Revision C APPENDIX Wiring Diagrams 7 20 Figure 7 26 P J Location 2 Figure 7 27 P J Location 3 ...
Страница 523: ...EPSON AcuLaser C8500 Revision C APPENDIX Wiring Diagrams 7 21 Figure 7 28 P J Location 4 Figure 7 29 P J Location 5 ...
Страница 524: ...EPSON AcuLaser C8500 Revision C APPENDIX Wiring Diagrams 7 22 Figure 7 30 P J Location 6 Figure 7 31 P J Location 7 ...
Страница 562: ...EPSON AcuLaser C8500 Revision C APPENDIX Component Layout 7 60 Figure 7 35 C311MAIN Component Layout Soldered Side ...
Страница 564: ......
Страница 565: ......
Страница 566: ......
Страница 567: ......
Страница 568: ......
Страница 569: ......
Страница 570: ......