17
GB
sensor (bench sensor - optional)
Connection of vaporizer
CAUTION:
When the vaporizer is activated, the output
"W" from the sauna heater is switched to
the terminal "Wb" to the vaporizer.
In this case, the sauna heater heats only
with two thirds of the power.
400 V 3 N AC 50 Hz
120°
X1
ECON
U
Lü
V
W
N
WB
L1 L2 L3
N
WM
Ligh
t
F
an
N
N
Li
N
V1 N S1
max. 3000 W
Installing the humidity sen-
sor (optional)
1. The humidity sensor is mounted in the cen-
tre of the cabin on the side wall opposite the
stove at a height of approx. 150 cm.
2. Please see Fig. 12 for the connection sequen-
ce of the wires.
3. Please ensure that the connection is made
precisely - incorrect connections can cause a
fault in the sensor.
The sensors are connected in the control unit to
the terminals as shown (Fig. 13).
Figure 12
Figure 13
Figure 14
1 2 3 4
Humidity sen-
sor
+UB
GND
E
br
o
wn
Blue
V
iolet
Programmed maximum values acc. to EN 60335-2-53:2012
During control via the humidity sensor, the sys-
tem is controlled via graphs; all values below or
on the characteristic curve can be set and used
(Fig. 14).
10
100
90
80
70
60
50
40
30
20
0
100
90
80
70
60
50
40
30
20
10
T
[° C]
rH
[%]
Allowed settings
Non-allowed settings
Assembly of a remote start mo-
dule
Then insert the sauna bus cable enclosed with
the remote start module into the designated
sauna bus connection. The other end is inserted
into the respective socket in the remote start
module. Now mount the remote start module
as shown in the enclosed instructions.
142°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
Ub
G
E
Auxiliary
temperature
Humidity sensor
(optional)