5
GB
Technical data
• Rated voltage:
400 V 3 N 50 Hz AC
• Switch output:
max. 9 kW resistive load (AC1 mode) Humidity mode:
6 kW + 3 kW for vaporizer equipment. Can be expan-
ded to 36 kW via the connection of power switching
devices
• Heat-up time restriction:
6 h, 12 h / without heat-up time restriction
• Display:
LCD display 65 x 37 mm, graphic
• Dimensions (HxWxD):
220 x 250 x 67 mm
• Protection class:
IPx4 acc. to EN 60529 splashwater protection
• Control range in the sauna mode:
30 to 115°C
• Control range in the humidity mode:
30 to 70°C
• Humidity control (without humidity sensor): time-proportional (10 levels)
• Humidity control (with humidity sensor): Permanent control via the humidity sensor F2 (with
humidity sensor Art.-No. 909479 or 945027 according
to EN 60335-2-53). See information!
• Sensor system (temperature):
PTC sensor with safety temperature limiter 142°C
• Water level monitoring:
Lack of water in the vaporizer will cause the heating
system to shut down after 2 minutes.
• Control characteristic:
Two-point control with fi xed hysteresis of 3K.
For control via the stove sensor off set of 7K to com-
pensate the higher temperatures directly below the
cabin ceiling
• Fan output:
max. 100 W, no capacitor motors, controlled via phase
control
• Light:
max. 100 W (automatic switching phase control / pha-
se cut-off )
• Re-heating:
30 min. at 90°C after the humidity program has been
stopped
• Ambient temperatures:
-10°C to +40°C
• Storage temperature:
-20°C to +70°C
• Temperature display stove sensor
Current value on the stove sensor minus 7K to com-
pensate the higher temperatures directly below the
cabin ceiling
• Temperature display bench sensor:
Current value on the bench sensor