43
EN
Only allow a specialist to carry out this work. Before working on the open control
unit, disconnect all poles from the mains. (Switch off the master switch, or trigger the FI
switch).
Risk of an electrical shock!
L1 L2
MAINS
L3 N W V U N
OVEN
N L
L N
WM
WB N
VAP.
Loosen the four screws on the opened unit that hold the circuit board.
Loosen screws
X2
F2
F1
L1 L2 L3 N W V U N
N L
Loosen screws
F1
F2
The control unit is fitted with two protective fuses which are mounted on the main relay board of
the unit. These fuses protect the electronics on the board and the light and fan outputs.
Notice
: fuses do not mean absolute protection, in an unlikely case of a power surge or a short
circuit with particularly fast voltage increase the electronic components may be still be affected.
Unit fuses
F1 = T 2A H 250V
Fuse electronics primary and light (*fan, if available)
F2 = T 315 mA L 250V Fuse of the electronics secondary
Relais PCB*
Display PCB
*) specific layout of the board and its components may
vary slightly from model to model.
Device fuses