background image

5

GB

Technical Specifi cations

Open container 0 bar

Heating output vaporise

2000 W at Bi-O-Star 15 / 18 kW

4000 W at Bi-O-Star 21 / 24 / 30 kW

your sauna bath, you can add water into the 
storage tank after the control unit had been 
put to „Stop“ 5 minutes before or has been 
operated for 5 minutes in the mode „Finnish 
Sauna“. The heating rod in the vaporiser 
must cool down for 5 minutes before cold 
water can be fi lled in.

   

Never fi ll water onto the red hot  

   

heating rod. Besides the risk of 

scalding, the heating rod could be da-
maged.

If any additives have once been added to 
the water, normally this can result in over-
boiling foamily water. In this case, the water 
must be discharged and the cold container 
must be washed out with a cloth that has 
been drenched in alcohol or spirit. Even the 
smallest residues of essences on the wall of 
the vaporiser change the natural structure 
of the water. 

Take care with control units that have follow 
up heating times. 

   

After  the  wet  bath,  never  leave 

the  

   

herb bags in the herb 

bowl during the follow up heating times. 
They  would  immediately  dry  out  and 
could cause fi re hazard!

Connection to Fixed Water Net 

We recommend the usage of a fi xed water 
connection, in order to prevent the vaporiser 
from running dry.

Decalcifying the Vaporiser

Please  ask  your  local  supply  company 
for the hardness of your water. Within the 
hardness degree I (1-7 German Degrees 
of  Hardness)  the  device  works  normally 
trouble-free and must only be decalcifi ed 
on demand.

If your water is within the degrees of hard-
ness II - IV, it is necessary to have the vapori-
ser decalcifi ed from time to time (depending 
on the degree of hardness). 

For this, add decalcifying agents for dome-
stic appliances to the water in the vaporiser 
according to manufacturer information. Bring 
the mixture of  water and decalcifying agents 
to a boil for ten minutes and have it cooled 
down subsequently. 

After it has been cooled down discharge the 
mixture from the vaporiser and rinse out with 
cold water at least twice. Please consider 
the instructions of the  manufacturer of the 
calcifying agents.

   

Attention!

   

The  device  must  be  separated 

from the power supply system in the case 
of any cleaning or maintenance jobs, in 
case accessory or plates are changed, 
or  in  the  case  of  any  repair  works  in 
operation mode.