5
GB
Technical Specifi cations
Open container 0 bar
Heating output vaporise
2000 W at Bi-O-Star 15 / 18 kW
4000 W at Bi-O-Star 21 / 24 / 30 kW
your sauna bath, you can add water into the
storage tank after the control unit had been
put to „Stop“ 5 minutes before or has been
operated for 5 minutes in the mode „Finnish
Sauna“. The heating rod in the vaporiser
must cool down for 5 minutes before cold
water can be fi lled in.
Never fi ll water onto the red hot
heating rod. Besides the risk of
scalding, the heating rod could be da-
maged.
If any additives have once been added to
the water, normally this can result in over-
boiling foamily water. In this case, the water
must be discharged and the cold container
must be washed out with a cloth that has
been drenched in alcohol or spirit. Even the
smallest residues of essences on the wall of
the vaporiser change the natural structure
of the water.
Take care with control units that have follow
up heating times.
After the wet bath, never leave
the
herb bags in the herb
bowl during the follow up heating times.
They would immediately dry out and
could cause fi re hazard!
Connection to Fixed Water Net
We recommend the usage of a fi xed water
connection, in order to prevent the vaporiser
from running dry.
Decalcifying the Vaporiser
Please ask your local supply company
for the hardness of your water. Within the
hardness degree I (1-7 German Degrees
of Hardness) the device works normally
trouble-free and must only be decalcifi ed
on demand.
If your water is within the degrees of hard-
ness II - IV, it is necessary to have the vapori-
ser decalcifi ed from time to time (depending
on the degree of hardness).
For this, add decalcifying agents for dome-
stic appliances to the water in the vaporiser
according to manufacturer information. Bring
the mixture of water and decalcifying agents
to a boil for ten minutes and have it cooled
down subsequently.
After it has been cooled down discharge the
mixture from the vaporiser and rinse out with
cold water at least twice. Please consider
the instructions of the manufacturer of the
calcifying agents.
Attention!
The device must be separated
from the power supply system in the case
of any cleaning or maintenance jobs, in
case accessory or plates are changed,
or in the case of any repair works in