6
GB
Connection diagram
Connection control panel
C o n n e c t i o n
circuitbraeker
device
Connection con-
trol panel
15 - 18 kW
21 - 30 kW
N
Wm
1
2000W
R
1
Wb
PE
2 kW
N
Wm
L
V2
2
1
2000W
2000W
2
R
R
1
Wb
PE
4 kW
L
V1
Capacity
acc. DIN
Vaporicer
-capacity
-volume
Electrical.
Connection
Fuse control
unit in A
Fuse LSG
in A
Connecting
cable main
- control unit
in mm²
Connecting
cable main
- LSG in mm²
Connecting
cable control
unit - heater
in mm²
Connecting
cable LSG
- heater in
mm²
Connecting
cable control
unit - LSG in
mm²
15 kW
2 kW
5 l
3N AC
50 Hz
400 V
3 x 16
3 x 16
5 x 2,5
5 x 2,5
5 x 1,5
4 x 1,5
5 x 1,5
5 x 1,5
18 kW
21 kW
4 kW
10 l
3 x 35
5 x 1,5
3 x 1,5
5 x 2,5
4 x 1,5
24 kW
5 x 6
5 x 4
4 x 1,5
30 kW
1 x 16
3 x 63
3 x 1,5
5 x 16
3 x 1,5
2 St. 5 x 4
1 St.4 x 1,5
6 x 1,5
All cross sections of a line are minimum diameters in mm² (Copper line)