Connection diagram

Connection control panel

C o n n e c t i o n 
circuitbraeker 
device

Connection con-
trol panel

15 - 18 kW

21 - 30 kW

N

Wm

1

2000W

R

1

Wb

PE

2 kW

N

Wm

L

V2

2

1

2000W

2000W

2

R

R

1

Wb

PE

4  kW

L

V1

Capacity 
acc. DIN

Vaporicer

-capacity

-volume

Electrical. 

Connection

Fuse control 

unit in A

Fuse LSG 

in A

Connecting 

cable main 

- control unit 

in mm²

Connecting 

cable main 

- LSG in mm²

Connecting 

cable control 

unit - heater 

in mm²

Connecting 

cable LSG 

- heater in 

mm²

Connecting 

cable control 

unit - LSG in 

mm²

15 kW

2 kW

5 l

3N AC

50 Hz
400 V

3 x 16

3 x 16

5 x 2,5

5 x 2,5

5 x 1,5
4 x 1,5

5 x 1,5

5 x 1,5

18 kW

21 kW

4 kW

10 l

3 x 35

5 x 1,5
3 x 1,5

5 x 2,5
4 x 1,5

24 kW

5 x 6

5 x 4

4 x 1,5

30 kW

1 x 16

3 x 63

3 x 1,5

5 x 16

3 x 1,5

2 St. 5 x 4

1 St.4 x 1,5

6 x 1,5

All cross sections of a line are minimum diameters in mm² (Copper line)