Please cut the length of the silicone-hose
that in connection between the two connec-
tion-pieces, left and right, the centre of the
hose does not drop down.
Put silicone hose onto both spouts of the
T-pieces and safeguard it with hose-band.
Fig 8.
Fig. 8
s i l i c o n e
hose
Operation with Vaporiser
Fill water up to the upper marking line with
appropriate jar via funnel tube. (15 - 18 kW
= 5 l, 21 - 30 kW = 10 l)
Fill in water until the water level at the glass
tube reaches the upper bracket (Fig 9). Do
not overfi ll.
Fig. 9
Attention:
At damp outlet risk of
scalding. Put herbs and essences
only into herb bowl.
The vaporiser will be regulated via the
control unit. You get a humidity value that
will either be regulated via a nominal/actual
value comparison at the sensor, or which will
be determined via a clock pulse.
Please note that the relative humidity values
will signifi cantly vary due to different tempe-
rature distributions in the cabin. Thus, the in-
dication at the hygrometer and the indication
at the control unit may signifi cantly differ.
Please check if the water tank is empty
prior to having a sauna. Remaining water
must be emptied out. Now, fi ll water into the
fi lling funnel up to the upper water gauge
(Fig 10).
Fig. 10
Herb bowl
Filling funnel
This amount is suffi cient for sauna baths of
two or three hours.
Please regulate the humidity degree at
the control unit. Never add essences,
essential oils or herbs to the water, but
put them into the herb bowl on the cover
of the vaporiser
The hot, ascending vapour releases essen-
tial oils which will be distributed in the cabin
automatically.
In case the store of water has been used
up, a ring tone sounds and indicates water
scarcity. However, if you want to continue