www.enware.com.au
Call 1300 369 273
25
STEP 1
To change the battery, the thermostatic valve must first be
closed and the faceplate, spout and dress flange removed
as per Step 1A - 1D Annual Maintenance Procedure.
SEE IMAGES 1A, 1B, 1C, 1D, on page 21.
STEP 2
Remove the battery from within the box by pulling the
battery casing vertically upward, and then disconnect it from
sensor cable.
STEP 3
Open the casing cover and change the battery. Use only
a 6V Lithium 2CR5 battery (Enware part - ENMS204).
Replace the battery casing cover.
STEP 4
Connect the battery casing to the sensor, making sure the
white line on the sensor cable connector aligns with the
moulded line of the battery casing. SEE IMAGE 44
STEP 5
Check that the sensor is working.
When the battery is first connected, a red LED should light
up in the sensor lens. Activate the sensor and check that
the solenoid clicks when the sensor is activated.
STEP 6
Re-install the battery into the box. Re-assemble the
faceplate, dress flange and spout.
STEP 7
Open the thermostatic valve and restore the temperature
setting. Use the 3/8” Allen key to turn the temperature gear
clockwise, and adjust until the water from the outlet reaches
the desired temperature - see Setting the Outlet Temperature
in Commissioning section on page 19.
Caution: Failure to align the connectors correctly
will result in damage to the sensor circuitry and
void warranty.
CHANGING THE BATTERY
For battery operated models only.
Enware Product Code:
ENMS204
- 6V Lithium 2CR5 Battery
ENMS205
- 6V Lithium 2CR5 Battery with casing
If the mixer fails to function, and there is a RED light displayed within the sensor when trying to activate
the product, this means that the battery is low in voltage and needs to be replaced.
IMAGE 44
ALIGN WHITE STRIP WITH
MOULDED LINE ON
BATTERY CASE