SERVICE AND MAINTENANCE
Prior to servicing the strainers, turn off both the hot and cold water supply
via the isolation valve within the inlet connectors.
SEE IMAGE 26
on page
19.
STEP 1
Using a 3/8” Allen key unscrew the eSQX™ check valve /
strainer assembly and remove from the mixer.
SEE IMAGES
28 & 29
STEP 2
The check valve / strainer assembly should be cleaned with
a dilute water solution of suitable descaling solvent (such
as CLR), checked for physical damage and then thoroughly
rinsed with clean water. SEE IMAGE 30
STEP 3
Ensure there is no debris caught within the sealing faces.
When service is complete, re-fit SQX™ check valve / strainer assembly
and hand tighten with the Allen key. Test for water tightness.
SERVICING THE STRAINERS AND CHECK VALVES
Enware Product Code:
ATMS693
- Strainer / Check Valve Assembly (1 Pair)