Component Maintenance Manual
12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
Fax (405) 382-0737
http://www.enviro-ok.com
Copyright © 2017
ATA 21-00-23
P a g e
|
62
Revision 10
June 1, 2017
9.2.6.3
Attach fan shroud to coil with mounting bolts, washers and nuts (refer to table 1,
Section 1.3 for torque specifications).
9.2.7
Assembly of Outlet Shroud
9.2.7.1
After insuring that the shroud/coil mating surfaces have been cleaned in accordance
with section 6, apply a 1/8 inch bead of RTV to outlet shroud/coil mating surface.
9.2.7.2
Attach fan / outlet shroud to coil with mounting bolts, washers and nuts (refer to table
1, Section 1.3 for torque specifications).
9.2.8
Assembly of Condenser Coil
9.2.8.1
Attach condenser fan shroud and outlet shroud to coil per 9.2.6 and 9.2.7.
9.2.8.2
Attach condenser coil to base support using 8 screws and washers. Torque per Table
1 and apply safety wire or cable.
9.2.8.3
Attach condenser support bracket with 7 screws and washers. Torque per Table 1 and
apply safety wire or cable.
9.2.8.4
Using a wire brush and cleaning solvent, completely remove old thread sealant from
compressor connection threads. Apply a thin layer of thread sealant primer to male
fitting threads.
9.2.8.5
Apply 1-2 drops of thread sealant on compressor fitting threads.
CAUTION
: TAKE EXTREME CARE NOT TO GET REFRIGERANT OIL ON FITTING THREADS
9.2.8.6
Apply a thin film of refrigerant oil to fitting flare surfaces.
9.2.8.7
Connect condenser fitting to compressor and tighten per Table 1.
9.2.8.8
Install receiver dryer per 9.2.9.
9.2.8.9
Secure condenser lines to condenser support bracket and base mounting bracket with
clamps as was removed.
9.2.9
Assembly of Receiver Dryer
9.2.9.1
Carefully slide receiver dryer into mounting clamp and tighten clamp.
9.2.9.2
Using a wire brush and cleaning solvent, completely remove old thread sealant. Apply
a thin layer of thread sealant primer to fitting threads.
CAUTION
: APPLY THREAD SEALANT SPARINGLY TO THREADS STAYING CLEAR OF FIRST 2-3
THREADS.
9.2.9.3
Apply 1-2 drops of thread sealant on receiver dryer inlet port threads.
CAUTION
: TAKE EXTREME CARE NOT TO GET REFRIGERANT OIL ON FITTING THREADS