![Enviro PILATUS PC12 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/enviro/pilatus-pc12/pilatus-pc12_component-maintenance-manual-with-illustrated-parts-list_2415940003.webp)
Component Maintenance Manual
12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
Fax (405) 382-0737
http://www.enviro-ok.com
Copyright © 2017
ATA 21-00-23
P a g e
|
3
Revision 10
June 1, 2017
REV
DESCRIPTION OF CHANGE-Continued
DATE
APPROVAL
7
SEC 9.2.6
replace belt tensioning instructions for use with Gates
Sonic Meter. Replace
Fig 4
with detail of meter use. Add new
Table 4
tensioning information. Renumber
Table 5
was Table 4
Typical Operating Values SEC
13.3.3
add refrigerant charge to
this section and omit table 5.
Table 3.5
change 3
rd
column title
from Service Hours to Unit Operating Hours
IPC
indicate part
numbers in detail list for motor and fan of -13 config.
ITEM
50C
was 1134192-1 is 1134192-13,
ITEM 60A
deleted was
1250232-4
11/11/11
BH
8
SEC 1.3 Table 1
Added row 2 .25-28 SET SCREW
EVAPORATOR BLOWER WHEEL 12-15 IN-LBS, changed
torque values for 6-32 SCREW was 7-9 IN-LBS is 8-10 IN-LBS,
changed torque values for 10-32 SCREW/BOLT was 60-75 IN-
LBS is 20-25 IN-LBS, changed ¼-28-UNF torque values was
135-185 IN-LBS is 50-70 IN-LBS, changed 5/16-24UNF was
270-360 IN-LBS is 100-140 IN-LBS, changed 3/8-24UNF torque
values was 270-360 IN-LBS is 160-190 IN-LBS
4/19/12
BS
9
•
Section 2.3.1
Added (Superseded by 1134400-53)
•
Section 2.3.2
Added (1134400-13/-53)
•
Section 11 Figure 10001
, 10001-10C, Was: 1134104-5
Is: 1134104-6
•
Section 11 Figure 10001
, 50C Was: 1134192-13 Is:
1134192-1 (Superseded by 1134192-15)
•
SEC. 9.2.4
Added instructions to replace drive motor
with incorporated thermal fuse
1/21/14
BS
10
- Updated drive motor brush removal an installation procedures.
- Remove references of SB11-102
- Added 1134400-56 configuration to title page
- Added note to IPL Figure 10001 for -56 configurations to be
returned for update to -53
- Minor formatting and spelling corrections
- Table 3.6 removed note to remove and replace blower motor
between 4900 – 5100 hours.
- Section 14.4.2 removed reference to General Motors Service
Bulletin 83-12-21
- Added 1134400-59 Configuration
- Removed Section 10.2.4.4.1 through 10.2.2.4.4 describing
procedures for replacing an 1134104-1 motor with an 1134104-
6 motor.
- Removed Section 13.6 Motor brush seating procedure
- Updated Table 2 Consumable Products to include Pilatus part
number where applicable and to specify Enviro part number.
6/1/17
BS