Component Maintenance Manual
12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
Fax (405) 382-0737
http://www.enviro-ok.com
Copyright © 2017
ATA 21-00-23
P a g e
|
60
Revision 10
June 1, 2017
9.2.4.3.5 Push the measure button on the meter, hold the sensor approximately 1 cm
(0.4 in) above the belt at the midway point between the pulleys.
•
Lightly strum the belt with finger to induce a vibration.
•
Record the results in Hz or Newton’s
•
Repeat 3 times (or more if necessary) to verify consistent readings
9.2.4.3.6 In A Noise Filled Environment, if microphone sensor fails to produce accurate
readings, connect inductive sensor.
CAUTION
: REMOVE THE TAPE AND MAGNET FROM BELT BEFORE PROCEEDING.
9.2.4.3.7 Tape the Small Magnet in the mid-span of the belt; push the measure button
on the meter. Hold the inductive sensor approximately 1 cm (0.4 in) above
the magnet
•
Lightly strum the belt with finger to induce a vibration.
•
Record the results in Hz or Newton’s
•
Repeat 3 times (or more if necessary) to verify consistent readings
9.2.4.4
Rotate compressor by hand through several revolutions and verify belt tracking.
Readjust as required.
9.2.4.5
Apply Loctite to drive pulley set screws and tighten (refer to table 1, section 1.3 for
torque specifications).
9.2.4.6
Tighten and secure compressor mounting bolts and washers (refer to table 1,
section 1.3 for torque specifications).