9.2.1.10 Lower the brushes back into position on the commutator.
9.2.1.11 Attach field winding leads and brush shunt wires to the terminals as shown. Place
the brush shunt terminal on the top of the other terminals. Orient the tab of the
shunt terminal such that the wires exit away from the brushes. Torque brush shunt
wire mounting hardware to 15 IN-LBS.