SUBTASK 21-00-23-00-002
5.3
Evaporator Module Assembly Disassembly Procedures
(Refer to Figure 10002/10003):
5.3.1
Removal of Evaporator Module Assembly
5.3.1.1
Refer to aircraft maintenance manual for removal of Evaporator Module Assembly.
5.3.2
Removal of Blower Motor/Blower Wheel (FIG. 10003, 10/20B)
5.3.2.1
Disconnect power leads and mark for later identification.
5.3.2.2
Remove upper motor attachment screws and washers.
5.3.2.3
Remove lower motor attachment screws, spacers, washers and clamp.
5.3.2.4
Remove attachment nuts and washers securing drip tray to escutcheon.
5.3.2.5
Carefully slide drip away from evaporator.
CAUTION:
USE EXTREME CARE TO PREVENT DAMAGE OR BENDING OF BLOWER WHEEL DURING
REMOVAL OF MOTOR AND WHEEL.
5.3.2.6
Cut RTV between blower motor and scroll using a putty knife.
5.3.2.7
Carefully slide blower motor/wheel from scroll.
5.3.2.8
Carefully remove blower wheel from motor shaft by loosening wheel set screw.
5.3.3
Removal of Expansion Valve (FIG. 10002, 10), (FIG. 10003, 60A)
5.3.3.1
Disconnect refrigerant plumbing lines and cap off immediately.
5.3.3.2
Remove expansion valve from evaporator fitting and cap off fitting immediately.
5.3.4
Removal of Air Filter (FIG. 10002, 20), (FIG. 10003, 70D)
5.3.4.1