background image

Safety Warnings & Recommendations

Please read this entire Owner’s Manual before installing or operating your Enviro Pellet Stove. 

Failure to follow these instructions may result in property damage, bodily injury or even death. 

Any unauthorized modification of the appliance or use of replacement parts not recommended 

by the manufacturer is prohibited. All national and local regulations and shall be complied with 

when operating this appliance.

Caution: Do not connect to any air distribution duct or system.

Warning:

 Never place wood, paper, furniture, drapes or other combustible materials within 48” (122cm) 

of the front of the unit, 12” (30.5cm) from each side, and 4” (10cm) from the back of the unit. Do not let 

children or pets touch it when it is hot. 
To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the 

installation instructions. An Enviro dealer will be happy to assist you in obtaining information with regards 

to your local building codes and installation restrictions.

FIRE EXTINGUISHER AND SMOKE DETECTION:

All homes with a pellet burning stove should have at 

least one fire extinguisher in a central location known to all in the household. Smoke detectors and carbon 

monoxide detectors should be installed and maintained in the room containing the stove. If either sounds 

the alarm, correct the cause but do not deactivate. You may choose to relocate the detection devises within 

the room; DO NOT REMOVE THE SMOKE OR CARBON MONOXIDE DETECTORS FROM THE ROOM.

CHIMNEY OR RUN AWAY FIRE: 

Call local fire department (or dial 911). Close the draft fully. Extinguish 

the fire in the burn pot liner with a cup of water and close the door. Examine the flue pipes, chimney, attic, 

and roof of the house, to see if any part has become hot enough to catch fire. If necessary, spray with fire 

extinguisher or water from the garden hose. IMPORTANT:

 

Do not operate the stove again until you are 

certain the chimney and its lining have not been damaged.

OPERATION:

 The door and ash drawer must be kept closed when the unit is in operation to prevent 

fume spillage and for proper and safe operation of the pellet stove. Also ensure all gaskets on the door 

are checked and replaced when necessary. 

Unit hot while in operation. Keep children, clothing and 

furniture away. Contact may cause skin burns.
CAUTION: 

When operating during adverse weather, if the unit exhibits dramatic changes in combustion 

stop using the unit immediately. 

FUEL

:  This stove is designed and approved to only burn wood pellets of any quality

, corn, wheat, barley, 

and grass.  Dirty fuel will adversely affect the operation and performance of the unit and may void the 

warranty. Check with your dealer for fuel recommendations. 

THE USE OF CORDWOOD IS PROHIBITED 

BY LAW. Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil.
SOOT:

 Operation of the stove with insufficient combustion air will result in the formation of soot which will 

collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house.  

Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. 

See: 

s

LideR

/d

ampeR

 s

etting

”.

CLEANING:

 There will be some build up of fly ash and small amounts of creosote in the exhaust. This will 

vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and 

clean the exhaust vent semi-annually or every two tons of pellets.
The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage 

prior to re-lighting after a prolonged shut down period.

ASHES:

 Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container 

of ashes should be on a non-combustible surface, well away from all combustible materials pending final 

disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained 

in the closed container until all cinders have thoroughly cooled.

5

Содержание M55-FS-2

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R A T I O N e n v i r...

Страница 2: ...Pallet 15 Clearances to Combustibles 16 Levelling Leg Adjustment 16 Thermostat Installation 16 Vent Termination Requirements 17 Outside Fresh Air Connection 18 Exhaust and Fresh Air Intake Locations...

Страница 3: ...tove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the bu...

Страница 4: ...wood pellet has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heater in a manner inconsiste...

Страница 5: ...again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for prope...

Страница 6: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTE...

Страница 7: ...15 5KW hr Table 1 M 55 FS Specifications Description Fuel type Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper...

Страница 8: ...l is Yellow The Light flashes during start up and when the Thermostat is in control of the Unit The Light stops flashing when the Exhaust Sensor closes 6 HEAT OUTPUT INDICATOR Shows the present Heat L...

Страница 9: ...ll not operate for the first five 5 minutes after the ON button has been pressed After the five 5 minutes it will pulse at the same interval as the feed auger When the start up sequence is complete th...

Страница 10: ...grill are removed for clarity Operating Instructions Figure 6 Slider Damper Plate in Unit Figure 7 Efficient Flame This unit is designed to operate within a negative pressure range that may only be ad...

Страница 11: ...ut Lowering the cover position will decrease output and raising it will increase output CAUTION Increasing output too much can cause the high limit sensor to trip flashing 4 If this occurs lower the p...

Страница 12: ...of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift the burn pot from the firebox...

Страница 13: ...ing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly ASH BOX Weekly...

Страница 14: ...otors has sealed bearings DO NOT lubricate this motor Check gaskets and replace if needed POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for adde...

Страница 15: ...to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for combustion outside F...

Страница 16: ...a location that is not too close to the unit but will effectively heat the desired area 2 Connect the Thermostat or Timer using a 2 x 18 gauge wire from the unit to the thermostat If the heat in the...

Страница 17: ...ination locations Table 2 Use in conjunction with Figure 7 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any ot...

Страница 18: ...irtight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting shoul...

Страница 19: ...ter to the floor using the four 4 holes in the pedestal Ensure the unit is electrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is m...

Страница 20: ...fastened with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the...

Страница 21: ...tallations have 3 to 5 feet 91 to 152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations ma...

Страница 22: ...Vertical section of vent pipe Horizontal frame for thimble 90o elbow Concrete Wall Clean out tee Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove...

Страница 23: ...stallations section and then finish it by performing the following refer to Figure 16 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that yo...

Страница 24: ...hen the pellet vent is installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward...

Страница 25: ...imney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 18 Hearth Mount Side View Figure 19 Heart...

Страница 26: ...ided to attach the kit to the rear of the unit as shown Please see kit instruction manual for more detailed installation instructions The stove must also be connected to an existing 6 flue where permi...

Страница 27: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 28: ...the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT If the Auger gear box does not...

Страница 29: ...eaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Turn the Heat Level up slightly poor q...

Страница 30: ...e Agitator Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blowe...

Страница 31: ...Coupler 50 1697 6 Convection Blower 80mm 50 2064 7 Enviro Gel Decal 50 322 8 Auger With Paddles 50 1161 9 Ignitor Coil Type 400 Watt 50 2142 10 Auger Stops Clear Rubber 50 1559 11 Auger Plate And Bush...

Страница 32: ...Set of 2 50 2047 39 Exhaust Starter Tube Including Gasket 50 2043 40 Auger Tube Cover 50 1410 41 Hopper Lid Including Hinge 50 2037 42 Firebox Top 50 2040 43 Agitator Drive Bracket 50 2038 44 Cast Fl...

Страница 33: ...33 Parts Diagram Components 27 1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 22 21 20 25 24 23 26...

Страница 34: ...Parts Diagram Steel 55 56 57 58 34 35 47 40 33 32 31 30 29 28 54 51 52 53 49 50 48 46 44 41 45 43 42 39 36 37 38 34...

Страница 35: ...als for which the unit is not certified by the EPA and void if not operated according to the Owner s Manual Exclusions An expanded list of exclusions is available at www enviro com help warranty html...

Страница 36: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _____________...

Отзывы: