Operating Instructions

c

ontRoL

 b

oaRd

 F

unctions

:

1.  ON/OFF BUTTON:

 Used to turn the unit ON and OFF manually.

2.  COMBUSTION AIR TRIM BUTTON:

 Increases or Decreases the Fan voltage by 2.5volts on all feed 

settings. When pressed all lights on Heat Level Indicator will come on except the one that is the set 

point. Hold Trim Button down and press the UP or DOWN Heat Level Arrow to adjust setting. #3 Light 

is the default setting.

  Depending on Fuel quality Ignition problems may occur at higher altitudes, this can be resolved by 

trimming the Combustion Fan to a higher setting.

3.  FUEL TYPE BUTTON: 

Used to switch between fuel type modes; Pellet (for all qualities of wood 

ON/OFF

FUEL TYPE

AUTO/OFF

HIGH/LOW

MANUAL

Premium Pellets
Regular Pellets
Multi-Fuel

FEED TRIM

HEAT LEVEL

OPERATION MODE

COMBUSTION 

AIR TRIM

1

2

3

4

5

1

2

3

4

5

8

7

6

pellets) and Multifuel (for all fuels including wood 

pellets). When set on Multifuel it will run at a reduced 

High Feed Rate with wood pellets. 

NOTE: 

Fuel Type can 

only be chnaged when the unit is cold.

4.  THERMOSTAT SWITCH:

 Sets the unit’s control mode; 

AUTO/OFF or HIGH/LOW (when using a Thermostat or 

Timer) or MANUAL.

5.  FUEL TYPE LIGHTS:

 Shows the present Fuel Type 

selected; Premium Pellets are Red, Regular Pellets are 

Green, and Multi-fuel is Yellow. The Light flashes during 

start-up, and when the Thermostat is in control of the 

Unit.  The Light stops flashing when the Exhaust Sensor 

closes.

6.  HEAT OUTPUT INDICATOR:

 Shows the present Heat 

Level output setting and the Feed Trim while it is being 

adjusted.

7.  HEAT LEVEL ADJUSTMENT BUTTONS:

 Changes the 

Heat Setting of the Unit from LO to HIGH.  Press the 

Arrow Up button to increase Heat, and Arrow Down to 

decrease Heat.

8.  FEED TRIM BUTTON:

  Used in conjunction with the 

Heat Level Adjustment Buttons to adjust the Feed Trim. 

It can be increased by two (2) feed settings or it can be 

decreased by two (2) feed settings. The Feed Trim can 

only be adjusted one setting at a time. 

Figure 2: Circuit Board Control Panel Decal

a

utomatic

 s

aFety

 F

eatuRes

 

oF

 y

ouR

 p

eLLet

 s

tove

:

A.  EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust 

temperature drops below 49

°

C (120

°

F). It will display a #3 flash code.

B.  HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93

°

C (200

°

F), the auger will 

automatically stop, the stove will shut down, and it will display a #4 flash code.  If this happens, call 

your local dealer to reset the 93

°

C (200

°

F) high limit switch.

 ALSO FIND THE REASONS WHY THE 

UNIT OVERHEATED.

C.  VACUUM SWITCH: Notifies when the unit has lost vacuum. This can be caused by either a combustion 

fan/vent failure, or simply the unit’s outer door, pedestal door, and/or hopper lid beening left open. It 

will display a #2 flash code.

8

Содержание M55-FS-2

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R A T I O N e n v i r...

Страница 2: ...Pallet 15 Clearances to Combustibles 16 Levelling Leg Adjustment 16 Thermostat Installation 16 Vent Termination Requirements 17 Outside Fresh Air Connection 18 Exhaust and Fresh Air Intake Locations...

Страница 3: ...tove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the bu...

Страница 4: ...wood pellet has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heater in a manner inconsiste...

Страница 5: ...again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for prope...

Страница 6: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTE...

Страница 7: ...15 5KW hr Table 1 M 55 FS Specifications Description Fuel type Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper...

Страница 8: ...l is Yellow The Light flashes during start up and when the Thermostat is in control of the Unit The Light stops flashing when the Exhaust Sensor closes 6 HEAT OUTPUT INDICATOR Shows the present Heat L...

Страница 9: ...ll not operate for the first five 5 minutes after the ON button has been pressed After the five 5 minutes it will pulse at the same interval as the feed auger When the start up sequence is complete th...

Страница 10: ...grill are removed for clarity Operating Instructions Figure 6 Slider Damper Plate in Unit Figure 7 Efficient Flame This unit is designed to operate within a negative pressure range that may only be ad...

Страница 11: ...ut Lowering the cover position will decrease output and raising it will increase output CAUTION Increasing output too much can cause the high limit sensor to trip flashing 4 If this occurs lower the p...

Страница 12: ...of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift the burn pot from the firebox...

Страница 13: ...ing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly ASH BOX Weekly...

Страница 14: ...otors has sealed bearings DO NOT lubricate this motor Check gaskets and replace if needed POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for adde...

Страница 15: ...to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for combustion outside F...

Страница 16: ...a location that is not too close to the unit but will effectively heat the desired area 2 Connect the Thermostat or Timer using a 2 x 18 gauge wire from the unit to the thermostat If the heat in the...

Страница 17: ...ination locations Table 2 Use in conjunction with Figure 7 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any ot...

Страница 18: ...irtight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting shoul...

Страница 19: ...ter to the floor using the four 4 holes in the pedestal Ensure the unit is electrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is m...

Страница 20: ...fastened with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the...

Страница 21: ...tallations have 3 to 5 feet 91 to 152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations ma...

Страница 22: ...Vertical section of vent pipe Horizontal frame for thimble 90o elbow Concrete Wall Clean out tee Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove...

Страница 23: ...stallations section and then finish it by performing the following refer to Figure 16 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that yo...

Страница 24: ...hen the pellet vent is installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward...

Страница 25: ...imney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 18 Hearth Mount Side View Figure 19 Heart...

Страница 26: ...ided to attach the kit to the rear of the unit as shown Please see kit instruction manual for more detailed installation instructions The stove must also be connected to an existing 6 flue where permi...

Страница 27: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 28: ...the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT If the Auger gear box does not...

Страница 29: ...eaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Turn the Heat Level up slightly poor q...

Страница 30: ...e Agitator Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blowe...

Страница 31: ...Coupler 50 1697 6 Convection Blower 80mm 50 2064 7 Enviro Gel Decal 50 322 8 Auger With Paddles 50 1161 9 Ignitor Coil Type 400 Watt 50 2142 10 Auger Stops Clear Rubber 50 1559 11 Auger Plate And Bush...

Страница 32: ...Set of 2 50 2047 39 Exhaust Starter Tube Including Gasket 50 2043 40 Auger Tube Cover 50 1410 41 Hopper Lid Including Hinge 50 2037 42 Firebox Top 50 2040 43 Agitator Drive Bracket 50 2038 44 Cast Fl...

Страница 33: ...33 Parts Diagram Components 27 1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 22 21 20 25 24 23 26...

Страница 34: ...Parts Diagram Steel 55 56 57 58 34 35 47 40 33 32 31 30 29 28 54 51 52 53 49 50 48 46 44 41 45 43 42 39 36 37 38 34...

Страница 35: ...als for which the unit is not certified by the EPA and void if not operated according to the Owner s Manual Exclusions An expanded list of exclusions is available at www enviro com help warranty html...

Страница 36: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _____________...

Отзывы: