background image

35

Sept 2015

Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and 
conditions herein set forth, this product against defects in material and workmanship 
during the specified warranty period starting from the date of original purchase at retail. 
In the event of a defect of material or workmanship during the specified warranty period, 
Sherwood reserves the right to make repairs or to assess the replacement of a defective 
product at Sherwood’s factory. The shipping costs are to be paid by the consumer. 
All warranties by Sherwood are set forth herein and no claim shall be made against 
Sherwood on any oral warranty or representation. 

Conditions

 

A completed warranty registration must be submitted to Sherwood within 90 days 
of original purchase via the online warranty registration page or via the mail-in 
warranty registration card provided. Have the installer fill in the installation data 
sheet in the back of the manual for warranty and future reference.

 

This warranty applies only to the original owner in the original location from date of 
install.

 

The unit must have been properly installed by a qualified technician or installer, and 
must meet all local and national building code requirements.

 

The warranty does not cover removal and re-installation costs.

 

Sherwood Industries Ltd. reserves the right to make changes without notice.

 

Sherwood Industries Ltd. and its employees or representatives will not assume 
any damages, either directly or indirectly caused by improper usage, operation, 
installation, servicing or maintenance of this appliance.

 

A proof of original purchase must be provided by you or the dealer including serial 
number.

 

This warranty is void if the unit is used to burn materials for which the unit is not 
certified by the EPA and void if not operated according to the Owner’s Manual.

Exclusions

An expanded list of exclusions is available at www.enviro.com/help/warranty.html
This warranty does not cover:

 

Damage as a result of improper usage or abuse. 

 

Damage caused from over-firing due to incorrect setup or tampering.

 

Damage caused by incorrect installation.

To the Dealer

 

Provide name, address and telephone number of purchaser and date of purchase.

 

Provide date of purchase. Name of installer and dealer. Serial number of the 
appliance. Nature of complaint, defects or malfunction, description and part # of any 
parts replaced.

 

Pictures or return of damaged or defective product may be required.

To the Distributor

 

Sign and verify that work and information are correct.

Sherwood Industries Ltd.

6782 Oldfield Road, Victoria, BC . Canada  V8M 2A3

Online warranty registration: www.enviro.com/warranty/

Warranty for Enviro 

Pellet

 Products

Category

One Year

Two Year

Limited Lifetime

 

(7yr) 

Parts 

(unit serial number required)

Firebox Brick Panels 

 (Cast)

Firebox 

Heat Exchanger

Burn Pot

Burn Pot Liner

Firebox Liner Panels w/Insulation

Ceramic Glass 

2

Pedestal / Legs 

(excluding finish)

Surround Panels 

(excluding finish)

Exterior Panels 

(excluding finish)

Up to 5 years

Electrical Components

Steel Brick Liner 

 (Metal)

Exterior Surface Finishing 

3

Labour

1   

Whereas warranty has expired, replacement parts will be warrantied for 90 days from part purchase date.  Labour not included.  

   Unit serial number required.

2

  Glass is covered for thermal breakage. Photos of box, inside of door, and unit serial # must be supplied for breakage due to shipping.

3

  Exterior Surface finishing covers Plating, Enamel or Paint and excludes colour changes, chipping, and fingerprints.

Gaskets not covered by Warranty.
Travel costs not included.
Cast Agitator: 1 year for pellet. Not covered when burning alternative fuels. (Cast agitators are a consumable item)

Содержание M55-FS-2

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R A T I O N e n v i r...

Страница 2: ...Pallet 15 Clearances to Combustibles 16 Levelling Leg Adjustment 16 Thermostat Installation 16 Vent Termination Requirements 17 Outside Fresh Air Connection 18 Exhaust and Fresh Air Intake Locations...

Страница 3: ...tove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the bu...

Страница 4: ...wood pellet has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heater in a manner inconsiste...

Страница 5: ...again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for prope...

Страница 6: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTE...

Страница 7: ...15 5KW hr Table 1 M 55 FS Specifications Description Fuel type Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper...

Страница 8: ...l is Yellow The Light flashes during start up and when the Thermostat is in control of the Unit The Light stops flashing when the Exhaust Sensor closes 6 HEAT OUTPUT INDICATOR Shows the present Heat L...

Страница 9: ...ll not operate for the first five 5 minutes after the ON button has been pressed After the five 5 minutes it will pulse at the same interval as the feed auger When the start up sequence is complete th...

Страница 10: ...grill are removed for clarity Operating Instructions Figure 6 Slider Damper Plate in Unit Figure 7 Efficient Flame This unit is designed to operate within a negative pressure range that may only be ad...

Страница 11: ...ut Lowering the cover position will decrease output and raising it will increase output CAUTION Increasing output too much can cause the high limit sensor to trip flashing 4 If this occurs lower the p...

Страница 12: ...of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift the burn pot from the firebox...

Страница 13: ...ing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly ASH BOX Weekly...

Страница 14: ...otors has sealed bearings DO NOT lubricate this motor Check gaskets and replace if needed POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for adde...

Страница 15: ...to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for combustion outside F...

Страница 16: ...a location that is not too close to the unit but will effectively heat the desired area 2 Connect the Thermostat or Timer using a 2 x 18 gauge wire from the unit to the thermostat If the heat in the...

Страница 17: ...ination locations Table 2 Use in conjunction with Figure 7 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any ot...

Страница 18: ...irtight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting shoul...

Страница 19: ...ter to the floor using the four 4 holes in the pedestal Ensure the unit is electrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is m...

Страница 20: ...fastened with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the...

Страница 21: ...tallations have 3 to 5 feet 91 to 152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations ma...

Страница 22: ...Vertical section of vent pipe Horizontal frame for thimble 90o elbow Concrete Wall Clean out tee Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove...

Страница 23: ...stallations section and then finish it by performing the following refer to Figure 16 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that yo...

Страница 24: ...hen the pellet vent is installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward...

Страница 25: ...imney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 18 Hearth Mount Side View Figure 19 Heart...

Страница 26: ...ided to attach the kit to the rear of the unit as shown Please see kit instruction manual for more detailed installation instructions The stove must also be connected to an existing 6 flue where permi...

Страница 27: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 28: ...the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT If the Auger gear box does not...

Страница 29: ...eaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Turn the Heat Level up slightly poor q...

Страница 30: ...e Agitator Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blowe...

Страница 31: ...Coupler 50 1697 6 Convection Blower 80mm 50 2064 7 Enviro Gel Decal 50 322 8 Auger With Paddles 50 1161 9 Ignitor Coil Type 400 Watt 50 2142 10 Auger Stops Clear Rubber 50 1559 11 Auger Plate And Bush...

Страница 32: ...Set of 2 50 2047 39 Exhaust Starter Tube Including Gasket 50 2043 40 Auger Tube Cover 50 1410 41 Hopper Lid Including Hinge 50 2037 42 Firebox Top 50 2040 43 Agitator Drive Bracket 50 2038 44 Cast Fl...

Страница 33: ...33 Parts Diagram Components 27 1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 22 21 20 25 24 23 26...

Страница 34: ...Parts Diagram Steel 55 56 57 58 34 35 47 40 33 32 31 30 29 28 54 51 52 53 49 50 48 46 44 41 45 43 42 39 36 37 38 34...

Страница 35: ...als for which the unit is not certified by the EPA and void if not operated according to the Owner s Manual Exclusions An expanded list of exclusions is available at www enviro com help warranty html...

Страница 36: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _____________...

Отзывы: