Operating Instructions
a
djustabLe
a
ugeR
c
oveR
s
et
-
up
:
The auger cover is located within the hopper.
This adjustment allows for greater control of the feed rate than offered by the feed trim positions on the
control panel. Due to varying density by volume in fuels it may be necessary to adjust this cover either up
or down to control the maximum output. Lowering the cover position will decrease output and raising it will
increase output.
CAUTION
Increasing output too much can cause the high limit sensor to trip (flashing #4).
If this occurs lower the position of the cover and manually reset the sensor before
continuing to operate the unit.
11
SPECIAL NOTES:
Fuel quality is a major factor in how the stove will operate. If the fuel has a high moisture content or ash content the
fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).