background image

3

Introduction

This manual is designed for the home owner in conjunction with the technical manual. *

R

ating

 L

abeL

 L

ocation

:

The rating label is located on the top of the hopper.

F

ueL

 Q

uaLity

:

Fuel quality is important, please read the following:

Your Enviro pellet stove has been designed to burn ¼” (6mm) dia wood pellets and other 

organic fuels. DO NOT use this appliance as an incinerator. DO NOT use unsuitable and non 

recommended  fuels,  including  liquid  fuels  as  this  will  void  any  warranties  stated  in  this 

manual. 

The performance of your pellet stove is greatly affected by the type and quality of fuel being 

burned. As the heat output of various quality fuels differs, so will the performance and heat 

output of the pellet stove.

CAUTION: It is important to select and use only fuel that are dry and free of dirt or any impurities 

such  as  high  salt  content.  Dirty  fuel  will  adversely  affect  the  operation  and  performance  of  the  unit 

and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet 

manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer 

for a recommended pellet type.

ASH: The ash content of the fuel and operation of your stove will directly determine the frequency of 

cleaning. The use of high ash fuels may result in the stove needing to be cleaned daily.  A low ash fuel 

may allow longer intervals between cleaning.

CLINKERING: [clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during 

the burning process]. This hard mass will block the air flow through the Burn Pot Liner and affect the 

performance of the stove. Any fuel, even approved types, may clinker.  Check the Burn-Pot Liner daily to 

ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner (when the 

unit is cold) and clean/scrape the clinkers out.  Clean the holes with a small pointed object if required.  

Refer to the section Routine Cleaning and Maintenance. 

FUEL FEED RATES: Due to different fuel densities and sizes, fuel feed rates may vary.  This may require 

an adjustment to the slider damper setting or to the auger feed trim setting.

Since Sherwood Industries Ltd. has no control over the quality of fuel that you use, we assume no liability 

for your choice in fuels.

FILLING FUEL HOPPER: Open lid on top of unit, check hopper for foreign objects, empty the bag into 

the hopper, and ensure hopper lid closes completely.

Store fuels at least 36” (1 m) away from the pellet stove.
WARNING:  Parts  of  the  appliance,  especially  the  external  surfaces,  will  be  hot  to  touch 

when in operation so use due care.

FLAMMABLE  LIQUIDS:  Never  use  gasoline,  gasoline-type  lantern  fuel,  kerosene,  charcoal  lighter 

fluid, or similar liquids to start or “freshen up” a fire in the heater.  Keep all such liquids well away from 

the heater while it is in use.

Содержание M55-FPIs640

Страница 1: ...LD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R...

Страница 2: ...o Locate Your Pellet Appliance 16 Removing Pellet Stove From Pallet 16 Installing the Inset Frame and Levelling 17 Clearances to Combustibles 18 Thermostat Installation 18 Vent Termination Requirement...

Страница 3: ...ove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the bur...

Страница 4: ...15 2015 Under specific test conditions this heater has been shown to deliver heat at rates ranging from 9 200 45 500 Btu hr Emissions Rating Label Serial No DATE OF MANUFACTURE J F M A M J J A S O N...

Страница 5: ...again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for prope...

Страница 6: ...y suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING A...

Страница 7: ...pe Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb...

Страница 8: ...feed settings When pressed all lights on Heat Level Indicator will come on except the one that is the set point Hold Trim Button down and press the UP or DOWN Heat Level Arrow to adjust setting 3 Lig...

Страница 9: ...t operate for the first five minutes after the ON button has been pressed After the ten minutes it will pulse at the same interval as the feed auger When the start up sequence is complete the unit wil...

Страница 10: ...water column 37 42 Pa This can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5 setting after one hour of burn time This adjustment is necessary for varyin...

Страница 11: ...o adjust this cover either up or down to control the maximum output of 55 000 BTU Lowering the cover position will decrease output and raising it will increase output CAUTION Increasing output too muc...

Страница 12: ...it 3 The agitator locks at the right rotate the top of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner o...

Страница 13: ...use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly...

Страница 14: ...N CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above...

Страница 15: ...2 Close up of Front Rail Quick Release Pin Thumb Screw 1 Remove Cast Ash Drawer Front 2 Slide open the Cast Top 3 Lift off Cast Sides 4 Clip Side Rails to unit 5 Attach Front Rail using the quick rele...

Страница 16: ...l units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space Combustion air may be obtained from...

Страница 17: ...e length of the bolts masonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace 5...

Страница 18: ...matically O will drop down t will return to pre and it will restar To Turn Off Stov AUTO OFF mo Pour d marrer qualit de supe carburants App pot de br lure h Pour faire fonct MODE HIGH L tre ajust s L...

Страница 19: ...llowable exterior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass t...

Страница 20: ...mes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The inlet must ha...

Страница 21: ...Chimneys 6 It is necessary to permanently seal any opening between the masonry of Figure 9 Masonry fireplace installation the fireplace and the facing masonry When installing the insert into a masonry...

Страница 22: ...from the fireplace from entering the chimney which will affect proper drafting of appliance Figure 10 Masonry fireplace positive flue installation A qualified installer should evaluate the existing fi...

Страница 23: ...st be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L venting and be installed with vent manufacturer s recomm...

Страница 24: ...st caused by airflow around the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe...

Страница 25: ...nation Installation Figure 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section o...

Страница 26: ...PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 I...

Страница 27: ...in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is approximately 24...

Страница 28: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 29: ...require vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the li...

Страница 30: ...of the Heat Level button make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn p...

Страница 31: ...Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black Whi...

Страница 32: ...uger Collar with Screw 50 968 14 Auger Motor 2rpm 50 2054 15 Exhaust Motor Capacitor including Strap 50 2053 16 Agitator Drive Shaft with Sprocket 50 1698 17 Motor Drive Sprocket 50 1700 18 Auger Moto...

Страница 33: ...of 2 50 2294 54 Bearings with Mounting Bolts Set of 4 50 2295 55 M55C FPI Milan Empress FPI 2 Amp Small Fuse 50 2302 56 M55C FPI Milan Empress FPI 4 Amp Small Fuse Ignitor 50 2303 57 Agitator Drive B...

Страница 34: ...2276 68 M55C FPI Cast Ash Door Chestnut 50 2282 68 M55C FPI Cast Ash Door DB 50 2299 69 M55C FPI Cast Surround Trim Only PD 50 2272 69 M55C FPI Cast Surround Trim Only Beach 50 2278 69 M55C FPI Cast...

Страница 35: ...Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37 35...

Страница 36: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 36...

Страница 37: ...Notes 37...

Страница 38: ...Notes 38...

Страница 39: ...cluding serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caus...

Страница 40: ..._____________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________________________...

Отзывы: