Routine Cleaning and Maintenance
EXHAUST PASSAGES (Biannually)
Figure 10: M55C-FPI Exhaust Passages.
1. Swing open the cast door,
and unlatch the firebox
door.
(Both removed for clarity)
2. Remove the burn pot
assembly and clean all
the parts.
3. Lubricate all screws with
penetrating oil.
4. Pull the Tube Scraper
Rod fully out. Remove
the firebox liner, and lift
out the firebox lower.
Vacuum the firebox and
firebox liner thoroughly.
5. Open the ash drawer;
remove the ash pan and
clean out the cavity.
6. Re-install the parts in
reverse order
7. Close all doors securely.
BLOWER MECHANISMS (Annually)
Unplug the stove and pull the unit forward to access the two blowers. Vacuum all dust from motors.
The blower motors have sealed bearings, DO NOT lubricate these motors. Check gaskets and replace if
needed.
Post season cLean-uP
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical
protection. It is very important that the stove be cleaned and serviced as stated above.
CLEANING PAINTED SURFACES
Please clean painted surfaces with a soft damp cloth.
FIREBOX LINER
The paint on the Firebox Liner may peel. This is due to extreme conditions applied to the paint and is in
no way covered by warranty.
DOOR GLASS REPLACEMENT
It is recommended that your dealer replace the glass if broken. The door glass is made of high temperature
PYRO CERAMIC. To replace the glass, unscrew and remove the six retainer nuts using a
5
/
16
” socket.
Remove the glass and any broken pieces. High temperature fiberglass tape should be used around the
glass in the same location as the original fiberglass. Insert the glass into the retainer and screw the door
to the retainer. The use of substitute materials is prohibited.
Use Enviro Part: #50-2119
FIREBOX LINER
FIREBOX LOWER
ASH PAN
ASH DRAWER
14
Содержание M55-FPIs640
Страница 36: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 36...
Страница 37: ...Notes 37...