Figure 13: Outside Vertical Installation.
Installation
o
utside
v
eRticaL
i
nstaLLations
:
To accomplish an outside vertical pipe installation, follow the “
H
orizontal
e
xHauSt
t
HrougH
W
all
i
nStallationS
”
section and then finish it by performing the following.
1. Install a tee with clean out on the outside of the house.
2. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent
straight and secure. All joints in the exhaust venting system must be fastened with at least three (3)
screws.
3. Install ceiling thimble and secure the flashing as you go through the roof.
4. Ensure that the rain cap is approximately 24” (61 cm) above the roof.
NOTE - This venting configuration is only for use with the Built-In installation.
Rain cap
Flashing
24"
(61 cm)
Tee with
cleanout
3" (7.5 cm)
Clearance
Support
bracket
Type "L"
vent