27
Secondary Installation
s
uRRounD
P
aneL
i
nstaLLation
:
Warning: The surround becomes hot when the unit is operating; ensure that the unit is turned off, and
that it has cooled to room temperature before begining this installation.
Height
Width
3-Sided Surrounds
24” (610 mm)
35
3
/
8
” (898 mm)
4-Sided Surround
29
5
/
8
” (754 mm)
35
3
/
8
” (898 mm)
Table 7: Surround Dimensions.
Please check components supplied with this kit. If components are missing or have been damaged,
contact your dealer, distributor or courier company before starting this installation.
IMPORTANT: The panel must not seal ventilation openings in the fireplace.
INSTALLATION (3 and 4 sided Surrounds):
Lift the face upright in front of the fireplace with the four (4) hooks pointing towards the fireplace. Slide
the hooks over their corresponding bushings (see Figures 44 & 45). Ensure the hooks are secure before
releasing the surround. The surround should be wiped with a damp cloth periodically.
REMOVAL:
Lift the surround straight up in order to unhook the notch on the hooks from the bushing. Pull the
surround away from the fireplace. Place the surround where it will not be damaged.
Figure 44: Bushing Locations.
Figure 45: Bushing and Hook Close-Up.
Access Panel
removed for Clarity
BURNER SWITCH WIRING INSTALLATION:
The burner switch supplied with the surround comes pre-installed and wired. The wiring from the burner
switch simply needs to be connected to the wiring on the E20 unit.
The wiring harness for the burner switch has one (1) blue wire, one (1) grey wire and two (2) purple
wires.
The blue wire connects to the blue wire on the E20 unit, the grey wire connects to the grey wire on the
E20 unit, and the purple wires are used to connect an optional thermostat.
CLEANING:
Painted surfaces should be periodically wiped with a damp cloth. Never clean the face when it is hot.