background image

Parts List

35

Reference 

Number

Part Description

Part Number

1

E20 2” to 3” Air Intake  Adaptor

50-1499

2

Flue Adapter Gasket

50-1490

-

 E20 15’  2” & 3” Flex Vent

50-1512

-

 E20 2” & 3” Flex Couplers

50-1513

-

E20 Vertical Vent Cap

50-1487

3

E20 Flue Adaptor and Bottom C/W Gasket

50-2351

4

E20 DV Flue Adaptor Bottom Gasket

50-1491

5

E20 Cabinet Back

50-2359

6

E20 Owners Manual

50-2261

7

E20 Conversion Kit NG to LP

50-2306

-

E20 Conversion Kit LP to NG

50-2307

8

Blank Orifice

50-343

9

E20 Door Release Tool

50-1500

10

Ember Nuggets Only 

50-2347

11

Ceramic Wool Embers Only

50-893

12

Domestic Power Cord (115V)

EC-042

13

Heyco Strain Relief

EC-044

14

FPI Burner Switch

EC-026

15

 E20 Pilot Shield

50-2350

16

E20 Valve Extension C/W Knob (Long)

50-2353

17

Fan Controller W/Knob and Decal 115V

EF-045

18

Fan Controller Knob W/Decal

EC-040

19

E20 Control Panel C/W Decal

50-2356

20

S.I.T. Piezo Ignitor

EC-023

21

E20 Control Panel Bushings (Set 2)

50-2352

22

E20 Control Panel Knobs (Set 2)

50-2355

23

E20 Burner Only

50-2358

24

E20 Door Complete

50-2348

25

E20 Glass C/W Gasket (21.75” X 13.575”)

50-2349

26

Dual Bulb Door Gasket (10ft)

50-634

27

E20 Valve Cover with Gasket

50-1492

28

E20 Valve Extension C/W Knob (Short)

50-2354

29

E20 Burner Tray Only

50-2357

30

E20 Fan Only 

50-2260

Содержание E20

Страница 1: ...ate This appliance is not convertible for use with other gases unless a certified kit is used WHAT TO DO IF YOU SMELL GAS Open windows extinguish any open flame Do not try to light any appliance Do not touch any electrical switch or use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 2: ...CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re light the stove Always keep the area around these appliances clear of combustibl...

Страница 3: ...oving Valve Cover 12 Fuel Conversion 12 Initial Installation 15 Clearances to Combustibles 15 Minimum Fireplace Size 15 Direct Vent Model 15 Preparing Your E20 For Installation 16 Venting Fireplace Inserts 17 Direct Vent Vertical Vent Termination 19 Electrical Requirements 21 Gas Line Connection 22 Adjusting The Pilot Flame 24 Secondary Installation 25 Optional Base Shelf Riser 25 Optional 3 and 4...

Страница 4: ...FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO E20 Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permanent wall thermostat for bedroom installations is required Consult the authority having local jurisdiction in your area IN USA see curr...

Страница 5: ... the unit and is attached to a rectangular metal sheet that is chained to the fireplace Dimensions 5 Figure 1 E20 Exterior Dimensions 20 350 12 175 15 000 22 750 24 057 18 164 2 127 7 761 10 956 13 658 17 036 14 650 9 561 1 285 1 939 13 114 12 005 7 349 17 726 8 853 2 233 10 956 9 502 ...

Страница 6: ...nd Extruded Surround Height 237 8 594mm 237 8 594mm 237 8 594mm Width 353 8 898mm 353 8 898mm 353 8 898mm Trimmable Surround Height Width 28 705mm 4113 16 1062mm Base Shelf Base Shelf Riser Height 1 41mm 2 54mm Width 383 8 975mm 36 937mm Depth Bottom 4 112mm Top 313 16 97mm 311 16 94mm 35 3 8 898mm 26 660mm 25 1 2 648mm 23 7 8 594mm 38 3 8 975mm ...

Страница 7: ...by hand do not try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING this gas valve has a lockout device w...

Страница 8: ...rning on or off this is the valve opening and closing Table 2 Normal Sounds Venturi Adjustment The venturi adjustment lever is located on the right side of the unit below the door see Figure 5 The venturi allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame...

Страница 9: ...e unit is turned on for the first time it should be turned onto high with the fan OFF for the first four 4 hours This will cure the paint logs gasket material and other products used in the manufacturing process It is advised that a door or window be opened as the unit will start to smoke which can irritate some people After the unit has gone through the first burn turn the unit OFF including the ...

Страница 10: ...ree times a season Do not clean the glass when it is hot Cleaning The Firebox Remove the logs carefully as they are very fragile Gently remove all the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and remove any lint from the burner and pilot At this time inspect the burner pan for cracking or severe warping If a p...

Страница 11: ... operate the fireplace with the glass removed Caution glass may Separate from door Figure 8 Door Release Figure 9 Door Removal Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism see Figure 8 and pulling the latch out then up over the lip on the door When the two 2 latches have been released tilt the door forward and then lift up to unho...

Страница 12: ...e firebox see Figure 13 Figure 10 Screws Holding Burner Tray in Place Figure 12 Screws Holding Valve Cover in Place Figure 11 Removing Burner Tray Figure 13 Removing Valve Cover Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing Warning This conversion kit shall be installed by a qualified service agency in accordance ...

Страница 13: ...emove the log set and ember material if they are installed 4 Using a T 20 screwdriver remove the four 4 screws that hold the burner in place pointed out in Figure 14 Slide the burner to the left see Figure 15 then up and out of the firebox 5 Convert the burner orifice a Remove the main burner orifice with a inch deep socket see Figure 16 Figure 16 Orifice Removal Figure 17 Orifice Replacement b Pu...

Страница 14: ...de the burner disconnected and open the shut off valve at the gas line to the unit 10 Use a small brush to apply a warm soapy water solution to all gas connections use a half dish soap and half warm water If a gas leak is present bubbling will occur Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape NEVER USE AN OPEN FLAME WHEN TESTING FOR LEAKS 11 Reconnect...

Страница 15: ...on combustible material must be installed in front of the unit Minimum Fireplace Size Table 3 Minimum dimensions of fireplace for E20 to be installed into Width At Front Width At Back Height Depth Fireplace Dimensions 24 616 mm 18 460 mm 18 3 16 462 mm 14 355 mm Direct Vent WARNING This appliance has been designed to draw room air for proper heat circulation from the sides and bottom of the unit a...

Страница 16: ...s located on the center top of the stove above the door opening see Figure 26 Slide the collar plate backwards Properly secure the vent collar plate to the flexible vent pipe liner s previously installed in the chimney Be careful not to over stretch the liner s 6 Place the unit part way into the fireplace Connect the household gas line into the NPT receptacle at the lower left rear of the unit usi...

Страница 17: ...d of non combustible materials Before starting refer to Initial Installation Preparing Your E20 For Installation Please reference the information in Table 4 and Figures 28 and 31 An approved chimney liner and rain cap must be used A throat connector or flashing must be installed to ensure a tight seal top performance safety and efficiency Carefully follow the manufacturer s instructions that accom...

Страница 18: ...Initial Installation QUALIFIED INSTALLERS ONLY 18 2ft 0 6m Minimum 3ft 0 9m Minimum Within 10ft 3m Roof ridge or any other portion of a building Figure 28 Roof Clearances ...

Страница 19: ...tallation 2 Stretch both the Ø3 76mm flex vent and the Ø2 51mm flex intake liner to the length needed to ensure the flex can be easily connected to the vent terminal 3 Install the flex pipe assembly up through the chimney ensure that the pipe slides through far enough to connect onto the Vertical Vent Cap Note For any chimney over 15 4 6m install the E20 15 2 3 Flex Vent part 50 1512 and the E20 2...

Страница 20: ...imney apply a bead of Mill Pac Black sealant to the Ø3 76mm pipe of the vent terminal refer to Figure 30 Slide the flex liner onto the vent terminal and secure with three 3 sheet The height for the vent must be between 10ft 3 05m and 35ft 10 67m Install sealed Vertical Vent Cap to prevent leakage of room air up through chimney The intake is 2 51mm and the exhaust is 3 76mm Measure the height of th...

Страница 21: ...e current CSA C22 1 Canadian Electrical Code Part 1 Safety Standards For Electrical Installations or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut...

Страница 22: ...workmanship like manner This access hole must be plugged with non combustible insulation after the gas supply line has been installed A shut off valve is not supplied with this unit but one should be installed The appliance and its shut off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds psig 3 45 KPa or the valve will be damaged...

Страница 23: ... valve cover burner tray brick panels refer to Secondary Installation Installing the Brick Panels log set and ember material refer to Secondary Installation Log Set and Ember Installation and the glass door Always check for gas leaks with a soap and water solution after completing the required pressure test NEVER USE AN OPEN FLAME FOR LEAK TESTING 23 Initial Installation QUALIFIED INSTALLERS ONLY ...

Страница 24: ...rvice in order to gain access to the valve from above The pilot adjustment screw can be found in Figure 35 OR Figure 36 Proper Pilot Flame 3 8 1 2 10 13mm Thermocouple Proper Flame Adjustment Initial Installation QUALIFIED INSTALLERS ONLY 1b The adjustment screw can be reached through the front of the unit using an eight inch flat head screw driver see Figure 35 for location on valve 2 Turn the ad...

Страница 25: ...elf and Riser are sold separately Installation 1 If unit is running turn it off and allow it to cool completely 2 When using more than one riser each level must be attached using nine 9 8 T 20 screws provided see Figure 37 3 If installing with riser s the Base Shelf is to be fastened to the riser s with one T 20 screw at each end of the back see Figure 38 Figure 37 Combining 2 Base Shelf Riser Fig...

Страница 26: ... be touched up with a high temperature metallic black paint available from your dealer INSTALLATION 1 Install the mounting bushings and screws for the trimable panel onto the E20 unit using a T 20 Torx screwdriver See Figures 39 and 41 for the installation locations 2 In the case of the 3 Sided Panel hang the surround on the appropriate hooks depending on the optional surround that will be used wi...

Страница 27: ...gures 44 45 Ensure the hooks are secure before releasing the surround The surround should be wiped with a damp cloth periodically REMOVAL Lift the surround straight up in order to unhook the notch on the hooks from the bushing Pull the surround away from the fireplace Place the surround where it will not be damaged Figure 44 Bushing Locations Figure 45 Bushing and Hook Close Up Access Panel remove...

Страница 28: ...ll the burner tray that comes with the kit into the E20 firebox by hanging the five holes on the back side over the 5 screws that come through the rear of the firebox 2 Install the pilot shield extension as shown in Figure 48 the burner has been removed for clarity The shield will fit around the outside of the pilot shield that is installed in the unit 3 Secure the burner tray to the firebox by in...

Страница 29: ...51 2 Add the first large rock in front of the pilot box as shown in Figure 52 It should rest on top of the burner and the pilot box 3 Add the rock accents as shown in Figure 52 and 53 DO NOT PLACE ROCKS IN THE AREA INDICATED DO NOT PLACE ROCKS HERE Figure 51 Glass Beads in Place LEAVE THIS AREA CLEAR Figure 52 Rock Accent Placement Figure 53 Rock Accent Placement ...

Страница 30: ... the back of the firebox see Figure 54 Place the back brick panel on the ledge and ensure the panel is flush at the bottom and top refer to Figure 55 Do not push at the center of the panel 5 Slide the front of the left brick panel into the left lip at the front of the firebox Ensure the panel is flush to the side of the firebox and the back brick panel while still being hooked behind the front lip...

Страница 31: ...left brick panel Figure 59 The top left log rests on the back log and utilizes the locater pin pointed out in Figure 58 Ensure it is flush against the left brick panel and against the back wall The placement of the logs is not arbitrary If they are positioned incorrectly the flames can be pinched and will not burn correctly The burner and one of the logs come with locator pins and ledges which mak...

Страница 32: ...r wool irregularly onto and around the front of the burner to create a realistic look The ember wool comes in chunks that can be ripped into smaller pieces The front log has been removed for clarity See Figure 63 for complete log and ember set up with the front log WARNINGS DO NOT pack this ember material as this could create an unsafe condition The pieces should be lightly placed so they don t bl...

Страница 33: ...place for the first time since the log set and embers have been installed replaced watch for ignition at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Remove the glass and rearrange the ember material making sure none of the burner ports air holes are blocked Never operate the fireplace with the glass door removed Figure 63 Log Set and Ember In...

Страница 34: ... screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile If low see Pilot will not remain lit Check th...

Страница 35: ...347 11 Ceramic Wool Embers Only 50 893 12 Domestic Power Cord 115V EC 042 13 Heyco Strain Relief EC 044 14 FPI Burner Switch EC 026 15 E20 Pilot Shield 50 2350 16 E20 Valve Extension C W Knob Long 50 2353 17 Fan Controller W Knob and Decal 115V EF 045 18 Fan Controller Knob W Decal EC 040 19 E20 Control Panel C W Decal 50 2356 20 S I T Piezo Ignitor EC 023 21 E20 Control Panel Bushings Set 2 50 23...

Страница 36: ...9G 50 1612 12 oz Can of Metallic Black Touch Up Paint PAINT 12 MB Reference Number Option Description Part Number 39 Regular Surround Panel E20 50 2250 40 Contemporary Surround Panel E20 50 2252 41 Extruded Surround Panel E20 50 2253 42 Trim able Surround Panel E20 50 2255 Rustic Red Brick E20 50 2256 43 Base Shelf E20 50 2258 44 Base Shelf Riser E20 50 2344 Fluted Liner E20 50 2361 Porcelain Line...

Страница 37: ...Parts Diagram Components 37 E20 Components 1 34 33 31 30 32 29 2 3 4 5 6 7 8 9 10 11 12 13 14 35 36 37 38 15 16 17 18 27 25 26 24 22 20 19 21 28 23 ...

Страница 38: ...Parts Diagram Options 38 40 46 41 42 44 45 43 39 E20 Options ...

Страница 39: ...must be provided by you or the dealer including serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purch...

Страница 40: ..._______________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VENT B VENT NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in WC MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE ___________________________...

Отзывы: