46
The C72I / C72ID needs a hard-wired power connection in order for the unit to operate. There is also a
battery pack that takes four AA batteries in case there is a power loss.
All electrical connections must be made by a certified electrician.
There is an electrical box located in the cabinet on the left side of the fireplace. The Power wire
connection is to be made inside the elctrical box. There is a strain relief
on the outside of the cabinet to secure the wiring in place.
C60I Models: Wire incoming power to the supplied receptacle as shown
in Figure 59.
C60ID Models: Remove the steel cover plate from the electrical box
and connect incoming power to the wires inside.
120V
Figure 59:
C72I
Receptacle Wiring
C72I / C72ID IPI Dual Covection Fan Kit (50-4173)
The C72I / C72ID has an optional dual convection fan kit that can
be installed at before or after the fireplace installation. The fans are
operated by the remote controller. The fans can be turned on or off at
anytime with the remote. There are also 6 different fan speed settings.
The fireplace must be electrically connected and grounded in accordance
with local codes or, in the absence of local codes, with the current CSA
C22.1 Canadian Electrical Code Part 1, Safety Standards For Electrical
Installations, or The National Electrical Code ANSI / NFPA 70 in the US..
CAUTION: When servicing controls, label all wires prior to disconnection.
Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing. If any of the original wire supplied
with the appliance must be replaced, it must be replaced with 18 AWG
wire with a temperature rating of 105°C.
Figure 60: C72I Fan Kit Wiring Diagram. See 50-4173 instruction manual for C72ID wiring diagram
Green
Fan
Receptacle
Inside Cabinet
White
Incoming
Power
120
VAC
Fan
Black
IFC
Initial Installation
QUALIFIED INSTALLERS ONLY
Содержание C72I
Страница 55: ...55 Parts Diagram 1 2 3 4 5 6 9 7 8 12 13 14 10 15 15 ...
Страница 57: ...57 Notes ...