29
Initial Installation
QUALIFIED INSTALLERS ONLY
6 15
16 "
176mm
132"
3353mm
39 78 "
1012mm
39 1
16 "
993mm
66"
1676mm
93 5
16 "
2371mm
c
oRneR
i
nstaLLation
:
The dimensions for installing a fireplace in the corner of a room are given in Figure 38. Refer to “
I
nstallatIon
- a
llowaBle
c
o
-
axIal
V
ent
c
onfIguratIons
” for allowable pipe lengths.
Do not interfere with the structural integrity of the walls. Shown below are minimum clearances; increasing
these dimensions is allowable as long as vent length remains in the allowable range. See vent graph for
details.
Figure 38:
Dimensions for a Corner Installation
Vertical Vent Shield
Horizontal
Vent Shield
Figure 39: Vent Shielding Install
IMPORTANT: All installations must include the
vertical vent shield. The horizontal vent shield
is only installed if the fireplace is horizontally
terminated with the minumum vertical rise of 30”.
If more than 30” of vertical rise is used in the
vent configuration no horizonal shield is needed.
See Figure 39 for shield install. Screws are pre-
installed in cabinet and horizontal vent shield. Use
a T-20 screwdriver or drill driver to remove screws
then install shields.