45
e
LectRicaL
R
equiRements
:
The fireplace must be electrically connected and grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For
Electrical Installations, or The National Electrical Code ANSI / NFPA 70 in the US.
WARNING: The electrical grounding instructions must be followed. The fan kit is equipped with a three-
prong (grounding) plug for your protection against shock hazard, and should be plugged directly into a
properly grounded three-prong outlet. DO NOT cut or remove the grounding prong from this plug.
CAUTION: When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 18
AWG wire with a temperature rating of 105°C
Figure 58: C72I Wiring Diagram
IFC
Main
Harness
Transmitter - TMFLSA
885 Gas Valve
IPI Pilot
Optional
Fan Kit
Proflame 2 System - Wiring Diagram
Main
On/Off
Power Cord
To
Battery
Holder
Flame S
ensor
Spar
k E
lec
tr
o
de
Optional
Light kit
Top
Light(s)
2A
3A
Initial Installation
QUALIFIED INSTALLERS ONLY
Note: For C72ID specific wiring diagram refer to the Dexen user manual supplied and
label attached to the fireplace.
Содержание C72I
Страница 55: ...55 Parts Diagram 1 2 3 4 5 6 9 7 8 12 13 14 10 15 15 ...
Страница 57: ...57 Notes ...
Страница 58: ...58 Notes ...