background image

SAFETY PRECAUTIONS

  

FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY 
READ THE FOLLOWING INFORMATION: 
 

 

All "ENVIROGAS" gas-fired appliances must be 

installed in accordance with these instructions.  
Carefully read all the instructions in this manual first.  
Consult the building authority having jurisdiction to 
determine the need for a permit prior to commencing 
the installation. 

 

 

NOTE 

Failure to follow these instructions could 

cause a malfunction of the fireplace that could result in 
death, serious bodily injury, and/or property damage.   

 

Failure to follow these instructions may also void 

your fire insurance and/or warranty. 
 
 

GENERAL 

 

Installation and repair should be done by a 

qualified service person.  The appliance should 
be inspected before use and at least annually 
by a qualified service person.  More frequent 
cleaning may be required due to excessive lint 
from carpeting, bedding material, etc.  It is 
imperative that control compartment, burners 
and circulating air passageways of the 
appliance be kept clean. 
 

 

Due to high temperatures the appliance 

should be located out of high traffic areas and 
away from furniture and draperies. 
Children and adults should be alerted to 
hazards of high surface temperatures and 
should stay away to avoid burns or clothing 
ignition. 
 

 

Young children should be carefully 

supervised when they are in the same room as 
the appliance.   
 

 

Clothing or other flammable material should 

not be placed on or near the appliance.   

 
FOR YOUR SAFETY

 

 

A qualified installer, service agency or the gas 

supplier must perform installation and service. 
 

 

This installation must conform with local codes or, 

in the absence of local codes with the current 
CAN/CGA -B-149  

installation code in Canada or the National Fuel Gas 
Code ANSI Z223.1.2 in the USA. 

 

 

To prevent injury, do not allow anyone who is 
unfamiliar with the operation to use the stove.   

 

 

Always keep the area around these appliances clear 

of combustible material, gasoline or other flammable 
vapors and liquids.   

 

 

These appliances should not be used as a drying 

rack for clothing or for hanging Christmas stockings or 
decorations. 

 

 

Due to the paint curing on the stove a faint odor 

and slight smoking will likely be noticed when the stove 
is first used.  Open a window until the slight smoking 
stops. Always connect this gas stove to a chimney and 
vent to the outside of the building envelope.  Never 
vent to another room or inside a building. Make sure 
you use the vent pipe that is specified. Make sure that 
the vent is properly sized and is of adequate height to 
provide the proper draft.  Inspect the venting system 
annually for blockage and any signs of deterioration. 

 

 

 Do not operate with cracked or broken 

glass.  Under no circumstances should this 
appliance be modified.  Parts that have to be 
removed for servicing must be replaced prior 
to operating this appliance.  Only parts 
supplied by ENVIROGAS should be used in 
this appliance and replacements should only 
be performed by a licensed or qualified service 
person.  

 

 

Never use solid fuels such as wood, paper, 

cardboard, coal, or any other flammable liquids etc., in 
this appliance. 

 

 

Do not use this heater if any part has been under 

water.  Immediately call a qualified service technician to 
inspect the heater and to replace any part of the control 
system and any gas control that has been under water. 

 

 

Do not abuse glass by striking or slamming door 

shut. 

 

 

 

 

2

Содержание EG-40 FPI. BV.

Страница 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life A qualified installer service agency or the gas supplier must...

Страница 2: ...installation must conform with local codes or in the absence of local codes with the current CAN CGA B 149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To preven...

Страница 3: ...certified chimney liner kit Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bedsitting room Must be installe...

Страница 4: ...approved methods 4 Place the electric cable so it can be connected to the power supply Push the unit into its final position in the fireplace insuring that it is stable and level Using the leveling le...

Страница 5: ...14 Wipe down all gold surfaces with a soft rag to remove fingerprints they may become etched when the unit is heated up 5...

Страница 6: ...ntle pillar to stove 10 25 cm B Stove to 8 wide mantle 12 31 cm Stove must sit on a non combustible surface the width and depth of the insert Maintain sufficient clearances for operation service and m...

Страница 7: ...located on public property 7 feet 2 1m minimum M Clearance under verandah porch deck or balcony 24 inches 60 cm minimum A vent shall not terminate directly above a sidewalk or paved driveway which is...

Страница 8: ...peration of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide CO poisoning and possibl...

Страница 9: ...ency Carefully follow the chimney manufacturer s instructions that accompany the liner kit Measure the height of the chimney before hand and purchase the appropriate kit Never attempt to over stretch...

Страница 10: ...arge build ups Do not pack down leave embers loose Place cast ember pieces between the door facing and the ember tray The curved edge is placed into the firebox Align the mitered corner edges DO NOT P...

Страница 11: ...11...

Страница 12: ...IONS 1 STOP Read the safety information above 2 Turn off all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out an...

Страница 13: ...2 Turn off all electrical power to the appliance if service is to be performed 3 Flip burner switch to the off position 13...

Страница 14: ...ding upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass s...

Страница 15: ...11...

Страница 16: ...t dealer Burners will not light when valve and burner switch are both on Defective switch check switch connections jump wires at switch Defective thermopile check connections to valve check voltage ac...

Страница 17: ...ode ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON CANADIAN STANDARDS ASSOCIATION RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Mi...

Страница 18: ...purple wires CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Electrical...

Страница 19: ...18 GAUGE 40 FEET 20 GAUGE 18 FEET 15...

Страница 20: ...12 mos 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out Remove the br...

Страница 21: ...line from the pilot assembly and remove the pilot injector Re install the pilot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE DO NOT reu...

Страница 22: ...nly thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under this...

Страница 23: ...del ___________________________________ Serial Number __________________ Date of Purchase __________ ________ ________ Date of Installation __________ ________ ________ ____ Natural Gas Nat ____ Propa...